ROOM SEALED FLUE OPTIONS
GREENSTAR OILFIT INSTALLATION INSTRUCTIONS
8 716 106 261b (01/07)
10
P
R
E
-
IN
ST
AL
LA
TI
O
N
L
B
L
D
D
B
L
B
B
C
D
A
E
E
E
E
L
B
E
L
D
D
B
E
L
B
E
VERTICAL TERMINAL OPTIONS:
80/125mmO
Camray 25/32 100/150mmO
Danesmoor & Heatslave
L = 6000mm (E + Bx6)
Camray 12/18 & 18/25
L = 8000mm (E + Bx8)
Camray 25/32
L = 8000mm (E + Bx8)
Camray 25/32
L = 7000mm (E + D + Bx7)
Camray 25/32
L = 7000mm (E + Bx7)
A - Horizontal terminal
B - Straight flue extension
C - Flue bend 90°
D - Flue bend 45°
E - Vertical Terminal Kit (incl. 90° elbow)
Danesmoor & Heatslave
L = 5000mm (E + D + Bx4)
Camray 12/18 & 18/25
L = 7000mm (E + D + Bx7)
Danesmoor & Heatslave
L = 5000mm (E + Bx5)
Camray 12/18 & 18/25
L = 7000mm (E + Bx7)