6
Table 5
SPECIFICATIONS
CENTRAL HEATING FLOW FITTING
22 mm Compression
CENTRAL HEATING RETURN FITTING
22 mm Compression
COLD WATER MAINS INLET FITTING
15 mm Compression
DOMESTIC HOT WATER OUTLET FITTING
15 mm Compression
GAS INLET FITTING
Rc ½ inch
PRESSURE RELIEF VALVE DISCHARGE FITTING
15 mm Comp.
OVERALL HEIGHT (including flue turret)
1055 mm
CASING HEIGHT
850 mm (33,5 in)
CASING WIDTH
400 mm (17,75 in)
CASING DEPTH
340 mm (13.5 in)
PACKAGED WEIGHT
43 kg
MAXIMUM LIFT WEIGHT
42 kg
PRIMARY WATER CAPACITY
1 litres
OUTPUT TO DOMESTIC HOT WATER
Modulating 7 to 23 kW
OUTPUT TO CENTRAL HEATING
10 to 20 kW
MAXIMUM COLD SUPPLY PRESSURE
12 bar (180 psi)
CENTRAL HEATING CIRCUIT
NOMINAL FLOW (
∆
T = 30°C)
10 l/m
PRESSURE HEAD CORRESPONDING TO NOMINAL FLOW
0,2 bar
CENTRAL HEATING FLOW TEMPERATURE
45°C - 90°C
MAXIMUM ADMISSIBLE PRIMARY WATER PRESSURE
2.65 bar
DOMESTIC HOT WATER PRODUCTION
WATER FLOW SELECTOR TURNED COMPLETELY TO THE RIGHT
TEMPERATURE RISE
51°C
HOT WATER FLOW RATE
2,5 - 6,5 l/min
MINIMUM WORKING PRESSURE FOR MAXIMUM FLOW RATE
0,35 bar
WATER FLOW SELECTOR TURNED COMPLETELY TO THE LEFT
TEMPERATURE RISE
25°C
HOT WATER FLOW RATE
4 - 13 l/min
MINIMUM WORKING PRESSURE FOR MAXIMUM FLOW RATE
1 bar
SPECIFIC RATE "D"
11.0 l/min
No
x
CLASSIFICATION
2
SEDBUK CLASSIFICATION
BAND E