The standard flue assembly length is from 225mm to 420mm.
An extension flue length from 420mm to 560mm is available.
A terminal guard, Type GC 393 545, is available from Tower Flue
Components, Vale Rise, Tonbridge, TN9 1TB.
Do not allow the flue terminal fitted to the outside wall to
become obstructed or damaged.

2.7 Controls

The ON/OFF switch will turn the mains electricity on and off at
the appliance.
The electronic control system and gas valve modulate the heat
input in response to the central heating and domestic hot water
temperature settings. 
The Central Heating Temperature control knob provides for the
selection of domestic hot water only (turned fully anti-clockwise)
or central heating and domestic hot water (turned clockwise).
The position of the Domestic Hot Water control knob will
determine the temperature of the water delivered to the tap or
shower or bath. 
A facia mounted programmer is available as an optional extra. A
remote mounted programmer may be connected to the
appliance.
The integral facia displays indicate the status of the appliance.
There is provision for the connection of a mains voltage room
thermostat and/or a frost thermostat.
The electronic controls prevent rapid cycling of the appliance in
the central heating mode.

2.8 System Notes
IMPORTANT
Check that no dirt is left in either the gas or water pipework
as this could cause damage to the appliance. Thoroughly
flush the heating system and the cold water mains supply in
accordance with the recommendations of BS7593: 1992.

The water pipe connections throughout a sealed system must be
capable of sustaining a pressure of up to 3 bar.
Radiator valves must conform to the requirements of 
BS 2767:1991.
The relief valve discharge must be directed away from any electrical
components or where it would cause a hazard to the user.
A drain cock to BS 2879 must be fitted to the lowest point of the
system.
For circuit design purposes it is important that due note is taken of
the information given in Table 3 relating to the available pump head.

2.9 Showers, Bidets, Taps and Mixing Valves

Hot and cold taps and mixing valves used in the system must be
suitable for operating at the mains pressure.
Thermostatically controlled shower valves will guard against the
flow of water at too high a temperature.
If a pressure equalising valve is used, set the Domestic Hot Water
temperature control knob to the ‘MAX’ position.
Hot and cold mains fed water can be supplied direct to an over-
rim flushing bidet subject to local Water Company requirements.
With all mains fed systems the flow of water from the individual
taps will vary with the number of outlets operated
simultaneously and the cold water mains supply pressure to the
property. Flow balancing using ‘Ball-o-Fix’ type valves is
recommended to avoid an excessive reduction in flow to
individual outlets. For further information contact Worcester
Heat Systems Technical Helpline.

2.10 Safety Considerations

The appliance must not be operated in a waterless condition.
The appliance must not be operated with the boiler inner casing
cover removed.
Work must not be carried out on the appliance without the gas
and electricity supplies being switched off.
Checks must be made to ensure that, where applicable, the
ventilation openings made into walls and partitions are of the
correct size and are not obstructed.

2.11 Operation
Domestic Hot Water:

With a demand for hot water the burner

will light at its maximum setting and then automatically adjust
its output to maintain the temperature of the delivered water.
When hot water is no longer required, the burner will extinguish.
The fan and pump may continue to run for a short period to
dissipate the residual heat from the appliance.

Central Heating:

With a demand for heating the burner will light

at its minimum setting and gradually increase to give the
maximum output. The output of the appliance is then
automatically adjusted to maintain the temperature of the
system. The output can reduce down to a minimum of 9.0 kW. If
the system no longer requires even the minimum output to
maintain the desired room temperature the burner will
extinguish. The fan and pump may continue to run to dissipate
the residual heat from the appliance. The appliance will remain
off for a fixed period of three minutes before re-lighting to
automatically meet the system requirements.

Domestic Hot Water and Central Heating:

The appliance will

supply heat to the central heating system as required. A demand
for domestic hot water at a tap or shower will override the
central heating requirement for the period of the domestic hot
water demand. When hot water is no longer required the
appliance will return to the central heating state and its 
normal mode of operation. 

3

Fig. 1. Appliance water flow diagram.

Boiler

1

2

3

4

5

6        7              8         9     10

11

12

13

1.  Automatic air

vent.

2.  Gas to water

heat 
exchanger.

3.  Circulating

pump.

4.  Water to water

heat

exchanger.

5.  Water

diverting
valve.

6.  CH flow.

7.  DHW out.

8.  Mains cold          

water in.

9.  CH return

10.Safety 

discharge.

11. Central heating

by-pass 
adjustment.

12.Pressure relief

valve.

13.Sealed system

expansion
vessel.           

Содержание 24CDi BF

Страница 1: ...ng Control To Domestic Hot Water and Central Heating Minimum 9 0 kW Maximum 24 0 kW IMPORTANT THIS APPLIANCE IS FOR USE WITH NATURAL GAS ONLY THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE GAS METER This appliance must be installed by a competent person in accordance with the Gas Safety Installation and Use Regulations 1998 Bosch Group ...

Страница 2: ... Worcester Heat Systems Technical Department Telephone 0990 266241 for advice on specific installations 2 1 General Information 2 1 1 The appliance is set to give a maximum output of 24kW to the domestic hot water and to the heating system The hot water flow rate is limited to a nominal 9 l min at a maximum temperature rise of 40 C 2 1 2 The sanitary water section of the appliance is suitable for ...

Страница 3: ... an over rim flushing bidet subject to local Water Company requirements With all mains fed systems the flow of water from the individual taps will vary with the number of outlets operated simultaneously and the cold water mains supply pressure to the property Flow balancing using Ball o Fix type valves is recommended to avoid an excessive reduction in flow to individual outlets For further informa...

Страница 4: ...60 22 Table 2 PUMP HEAD BOILER OUTPUT HEAD MIN FLOW RATE FLOW RETURN DIFFERENTIAL kW Btu h Metres Feet L min Gal Min C F 9 0 30 700 4 8 15 7 11 7 2 57 11 C 20 F 24 0 81 900 2 0 6 6 20 5 4 5 12 5 C 22 F Table 3 MECHANICAL SPECIFICATIONS CENTRAL HEATING FLOW COMPRESSION 22mm CENTRAL HEATING RETURN COMPRESSION 22mm COLD WATER INLET COMPRESSION 15mm DOMESTIC HOT WATER FLOW COMPRESSION 15mm GAS INLET R...

Страница 5: ...T 30 RISE 12 4 l min MAXIMUM DOMESTIC HOT WATER FLOW RATE FROM APPLIANCE AT 40 RISE 9 0 l min NOx CLASSIFICATION Class 3 Table 5 DOMESTIC HOT WATER TEMPERATURE RISE DISCHARGE RATE l min 7 8 9 10 TEMPERATURE RISE C 49 42 9 38 1 34 3 Table 6 GAS SUPPLY SYSTEM BASED ON NG G20 TOTAL LENGTH OF GAS SUPPLY PIPE meters 3 6 9 GAS DISCHARGE RATE m3 h PIPE DIAMETER mm 2 9 15 8 7 5 8 4 6 22 18 0 12 0 9 4 28 T...

Страница 6: ...rforated non combustible partition Expanded metal or rigid wire mesh are acceptable provided that the major dimension is less than 13mm See BS 6798 1987 4 9 The distance between the inner face of a cupboard door and the cabinet front should not be less than 75mm 4 10 The pipe connection positions on the manifold are shown in Fig 3 allowing the system to be pre piped and flushed before the applianc...

Страница 7: ...fer to BS 6798 and BS 5440 2 for additional information 6 3 There must be sufficient clearance around the appliance to allow proper circulation of ventilation air The clearances required for Installation and Servicing will normally be adequate for ventilation 6 4 The minimum free areas required are given below 6 5 Refer to BS 6798 and BS 5440 2 for additional information 6 Air Supply 5 Siting The ...

Страница 8: ... 7 10 Connections to the mains water supply must not be made without the authority of the local Water Company 7 11 The pump is set at maximum and must not be adjusted 7 12 Connections in the system must resist a pressure of upto 3bar 7 13 Radiator valves must conform to BS2767 10 7 14 Other valves used should conform to the requirements of BS1010 7 15 No special system inhibitor is needed 8 1 The ...

Страница 9: ...essel kit is available from Worcester Heat Systems Ltd A thread sealant compatible with potable water must be used 10 3 The final 600mm of the mains cold water connection to the appliance should be made in copper tube only 10 4 The appliance is suitable for a mains pressure of up to 10 bar 150 lb in2 10 5 The appliance is fitted with a mains supply isolating valve 10 6 The maximum domestic hot wat...

Страница 10: ...r mains voltage operation and the leads securely fixed in the clamps provided The controls must be earthed at the connection on the control board Refer to Fig 13 11 8 A programmer to fit into the facia is available to control the CH Full instructions are sent with the programmer Refer to Fig 15 11 9 A clock to fit into the facia is available to control the operation of the central heating 11 10 On...

Страница 11: ...ark Indicators Settings Regulator valve CH demand indicator Red Spark electrodes DHW demand indicator Red Flame detect indicator Red Main valve Main valve Flow switch CH sensor DHW sensor Flame sense Overheat cut off 24V programmer Reset button Gas valve mode switch CH pressure adjust pot CH Control knob DHW control knob Convert AC to low voltage electronics Electronics microprocessor Safety Low V...

Страница 12: ...Cover Fixing Screws Fig 13 Mains Voltage External Controls Connections 230 V Room Thermostat Connections Ns Ls LR Spare ST8 Ns Ls LR Spare ST8 Remove Link Neutral Live Switched Live Neutral Live Switched Live Motor 230 V Programmer Connections 230 V room thermostat and Programmer Connections Ns Ls LR Spare ST8 Neutral Live S w it c h e d L iv e Neutral L i v e S w i t c h e d L i v e Motor Fig 14 ...

Страница 13: ...ng screws Remove the flue hood by releasing the clip at the front and pulling forwards 12 3 AIR AND FLUE DUCT PREPARATION AND ASSEMBLY From the carton containing the flue kit remove the flue terminal flue duct and the package containing 4 No 8 wall plugs 1 roll ducting tape 4 No 8 wood screws 1 tube of silicone sealant Separate the air and flue ducts from the terminal Measure the distance from the...

Страница 14: ...T 12 See Fig 8 Connect any room and or frost thermostats The electrical leads must pass through the appropriate space in the control panel and be fixed with the cable clamps provided See Figs 11 and 12 Refit the facia panel Test the gas supply pipework up to the appliance for soundness as indicated in BS 6891 Refer to Section 13 2 for a full description of the filling venting and the pressurising ...

Страница 15: ...he facia panel to gain access Refer to Section 15 3 c Set the Expansion Vessel Pressure The charge pressure of the expansion vessel as dispatched is 0 5 bar which is equivalent to a static head of 5 metres 17 ft The charge pressure must not be less than the static head at the point of connection Refer to Fig 18 A Schraeder type tyre valve is fitted to the expansion vessel to allow the charge press...

Страница 16: ...oom thermostat and the Central Heating Temperature Control to maximum Set the DHW temperature control to MIN On sealed systems check that the system is pressurised and set to the required pressure as indicated on the gauge Set the Programmer if fitted to HEATING WATER Set the operating switch to ON The burner will light The appliance will modulate its output from 9 0 to 24 0 kW over a period of ab...

Страница 17: ...and automatically balance with the system requirements Set the Operating Switch to OFF and the burner will go out 13 5 COMPLETION OF COMMISSIONING Disconnect the pressure gauge from the gas valve and tighten the test point screw Restart the appliance and check for gas soundness around the test point screw Refit the cabinet front panel If the appliance is being passed over to the user immediately r...

Страница 18: ...Undo the two screws securing the flue hood Lift and slide the flue hood assembly from the appliance See Fig 26 When refitting the hood ensure that the rear return edge passes under the lip at the rear of the combustion chamber f Combustion Chamber Front and Sides Remove the inner casing cover Slacken off to the end of the thread but do not remove the two wing nuts securing the combustion chamber U...

Страница 19: ...r casing cover as described in Section 15 3 b Drain the central heating circuit as described in Section 16 3 a Remove the circlip and lift the assembly from the appliance Unscrew air vent from the pipe Check the condition of the fibre washer Fit the replacement assembly making sure the O ring is in good condition Ensure that the circlip is correctly fitted and the dust cap is loosened Open the val...

Страница 20: ...nces the minimum pressure setting Start the appliance in the domestic hot water mode as described in Section 13 4 Appliance Operation Turn the gas valve mode switch on the rear of the facia to maximum Adjust the maximum pressure adjustment screw on the gas valve to give a burner pressure of 13 2 mbar for natural gas Turn the gas valve mode switch on the rear of the facia to minimum Adjust the star...

Страница 21: ...pipe Open the valves and fill and re pressurise the system as described in Section 13 2 15 Water Diverting Valve Micro Switch Assembly Refer to Figs 30 33 Check that the electricity supply to the appliance is turned off Hinge down the facia panel as described in Section 15 3 c Remove the bottom panel as described in Section 15 3 d Using a pair of fine nosed pliers pull the circlip off and remove t...

Страница 22: ... Remove the securing bracket from the valve and the water filter from the valve cold water inlet Retain the plastic manifold fixing screws support bracket and water filter Discard the water diverting valve Reassemble the original support bracket water filter and new O ring seals to the replacement valve Lubricate the O ring seal and push the plastic flow manifold onto the valve Reassemble the wate...

Страница 23: ...emble in the reverse order ensuring the fibre washers and O rings are in place 20 Pressure Gauge Refer to Figs 30 34 Check that the electricity supply to the appliance is turned off Drain the central heating circuit as described in Section 16 3 a Hinge down the facia panel into the servicing position as described in section 15 3 c Remove circlip and pull out the capillary sensing bulb in the retur...

Страница 24: ... one direction only Locate the replacement control board over the four mounting posts and push back squarely until the plastic catch on the end of each post clicks into place Reassemble in the reverse order and ensure i the spark electrode leads are re connected Polarity is not important ii the connectors are fitted to the correct terminals Connectors are not interchangeable and will only fit the ...

Страница 25: ...42 800 0 68 E00 716 Automatic Air Vent Intermes ref 02 05 010 1 8 716 140 500 0 85 299 506 System Pressure Gauge Cewal spec D2111 1 8 716 142 300 0 40 375 699 Pressure Relief Valve Caleffi ref 312439 1 8 716 142 404 0 29 173 006 Circulating Pump Grundfoss ref 50 50 6601 1 8 716 143 100 0 25 173 001 Expansion Vessel Zilmet ref 301010 1 8 716 142 500 0 42 299 353 Water to Water Heat Exchanger Gianno...

Страница 26: ...26 ...

Страница 27: ...e gas to maintain flow temperature set by control knob DEMAND END Pump continue four minutes CENTRAL HEATING FUNCTION AND AND AND DOMESTIC HOT WATER FUNCTION MAIN SWITCH ON Green Light On Flow switch On Top open DOMESTIC HOT WATER DEMAND Priority over CH demand HW light On Pump On Ignition Sequence Burner on Four second ramp to max gas pressure Modulate gas to maintain delivered water temperature ...

Страница 28: ... FUNCTION AND Above 9 C Commence normal central heating mode until temperature reaches 30 C 5 C to 9 C Below 5 C No demand and primary temperature below 8 C Internal Autofrostat demand Wait in normal off state for 30 minutes Run pump for four minutes Monitor central heating sensor Return to normal off state AUTOFROSTAT FUNCTION ...

Страница 29: ...y flashing they can also be used to help provide fault diagnostics Therefore with individual or groups of lights being permanently off on or flashing every normal fault can be identified To use the fault finding system select a box below which represents the light situation during your fault Then refer to the appropriate following section This fault finding system assumes that the appliance has be...

Страница 30: ...to boiler Replace control board Section 16 4 22 FAIL POINT A No No Yes Yes Yes No Replace fuse This will be caused by fuse fatigue or by the board Has fuse F2 blown Replace control board Section 16 4 22 Remove control board from facia See Section 16 4 22 and sepa rate transformer from board Measure resistance across the two pairs of adjacent pins on the transformer Is any pair above 100 ohms Repla...

Страница 31: ...mmer Yes Yes Red diode is damaged Replace control board Section 16 4 22 Replace control board Section 16 4 22 With a hot water tap fully open does the boiler ignite and appear to run normally in hot water mode Remove multiway connector from board position ST16 With tap still open is there continuity across contacts 19 and 20 2 pink wires Remove the black cover from the microswitch assembly With ta...

Страница 32: ...pressurised and is all air vented Rectify fault FAIL POINT G Primary Overheat No Re fix sensor to pipe No Repair or replace pump Section 16 4 12 No Reset the controls and restart the boiler Does the pump run Yes Remove inner casing cover and inspect the primary sensor left of heat exchanger Is it correctly fixed to pipe Yes Fault caused by control board or primary heat exchanger Yes Remove the mul...

Страница 33: ...ve Section 16 4 9 Remove inner cover Reset and restart the boiler Does a spark occur across the electrodes Turn off boiler Remove the multiway connector from board position ST16 Test resistance across contacts 7 and 8 brown wires and 9 and 10 violet wires Are both reading below 100 ohms Replace control board Section 16 4 22 Repair or replace flame sensor Section 16 4 8 or wiring Replace gas valve ...

Страница 34: ...alve Section 16 4 9 Remove both brown connectors from gas valve Is there continuity from brown and violet wires to the multiway connector Check or replace CH sensor Section 16 4 10 Is there continuity from contacts 17 and 18 to DHW sensor Check or replace DHW sensor Section 16 4 11 Is there continuity from contacts 12 and 13 to CH sensor Repair or replace harness Repair or replace harness Repair o...

Страница 35: ... set to maximum Remove multiway connector from board position ST16 Is the resistance across contacts 1 and 2 blue wires below 60 ohms Remove blue top connector from gas valve Is there continuity along blue wires to multiway connector Is the gas set to correct pressure Set pressure No No Repair wires or replace harness No Yes Yes Replace gas valve Section 16 4 9 Replace control board Section 16 4 2...

Страница 36: ...anged in the interests of continued improvement All goods sold are subject to our official Conditions of Sale a copy of which may be obtained on application PUBLICATION 8 716 145 063g 10 99 Bosch Group Worcester Heat Systems Limited Cotswold Way Warndon Worcester WR4 9SW Telephone 01905 754624 Fax 01905 754619 Technical Helpline 0990 266241 ...

Отзывы: