34
18. Operational Flow Diagram
M
ains
230V
supply
BOILER
HEA
T
DEMAND
Pump
continues
for
4
minutes
DEMAND
OFF
Boiler demand
fr
om sy
stem
junction bo
x
AND
User contr
ol
knob ON
Run f
an
20
seconds
or w
ait f
or
the end of
the f
an
ov
errun
Boiler
demand
light on
Pump
supply
on
Ignition
sequence
Boiler cy
cles
to satisfy
temper
atur
e
set b
y f
acia
contr
ol
knob
Temper
atur
e
Sensor disconnected
Ignition sequence inhibited
(f
an and pump ma
y run f
or
short period)
Boiler
ov
erheat
Ov
erheat
thermost
at
trip.
Lock
out
light
(const
ant)
Pr
otection Sy
stems
re-attempt
ignition
(MAX 4
times)
lock
out
light
(flashing)
Fa
n
continues
for
1
minute
FAIL
PASS
PASS
FAIL
Run pump
continuously