User manual
SA0061 Cattle Crush
Version: 09-07-18
Page 39 of 47
6.5. Check fluid level/replace fluid.
Emptying the accumulator/gauging the fluid level
No.
What to do
Action
Outcome
1. Retract the cylinders.
Put the cylinders in the installation in
their retracted position by operating the
valves.
2. Allow the accumulator
to empty.
Ensure that the air bleed valve is in its
open position on the lower manifold.
(Figure 6)
3. Disconnect the
machine from the
power supply
The accumulator will empty, the
hydraulic system will be depressurised.
The accumulator
will gradually
empty.
4. Check the fluid level.
The oil level must now be between the
minimum and maximum levels (see
instructions on "changing the oil").
EXPLANATION
Checking the fluid level ensures that the necessary minimal amount of fluid
is present. The cylinders must be retracted for this purpose and the
accumulator must be empty. The plug must be removed from the socket.
The general rule is that the fluid and filter should be replaced every two
years.