WSP-SM40 Rev. 1.2
http://www.woosim.com
16
Change the mode and option using the mode Code.
MODE button
: changing Printer OPTION status. (
Error Lamp
)
FEED button
: changing MODE status.
[Example] The defaults of the printer are :
UART / 9600 bps / 8 data bit / No parity /1 stop bit / Density low /
Quality low / Mark use / Sensor low
If a user wants to modify the defaults with
Bluetooth / 57,600 bps / 7 data bit / Odd parity /2 stop bit / Density high /
Quality high/ Mark no use / Sensor medium1
Press
MODE Button
during the
Error Lamp
flickers 5 times.
You will see present
COMMUNICATION
mode in the LCD. (UART)
Press the
MODE Button
twice. And then, interface mode has set to
Bluetooth
mode.
When you press
FEED button
once.
You will see present
BAUD RATE
mode in the LCD. (9600 bps)
Press
MODE Button
3 times. And then,
BAUD RATE
has set to
57,600 bps
.
When you press
FEED button
once.
You will see present
DATA BIT
mode in the LCD. (8 Data bit)
Press
MODE Button
once. And then Data Bit has set to
7 DATA BIT
.
When you press
FEED button
once.
You will see present
PARITY
mode in the LCD. (No parity)
Press
MODE Button
once. And then the Parity bit has set to
ODD Parity Bit.
.
When you press
FEED button
once.
You will see present
STOP BIT
mode in the LCD. (1 stop bit)
Press
MODE Button
once. And then the density has set to
2 Stop bit
.
When you press
FEED button
once.
You will see present
DENSITY
mode in the LCD. (Density low)
Press
MODE Button
twice. And then the density has set to
Density high
.