http://www.woosim.com
15
X
Press
FEED Button
one time,
Power Lamp
twinkles 3 times and
Error Lamp
twinkles 2 times.
o
Press
MODE Button
one time,
Error Lamp
twinkles one time.
(The Data Bit has set to 7 data bit)
X
Press
FEED Button
one time,
Power Lamp
twinkles 4 times and
Error Lamp
twinkles 1 time.
o
Press
MODE Button
one time,
Error Lamp
twinkles 2 times.
(The Parity bit has set to even parity bit)
X
Press
FEED Button
one time,
Power Lamp
twinkles 5 times and
Error Lamp
twinkles 1 time.
o
Press
MODE Button
one time,
Error Lamp
twinkles 2 times after then
press
MODE Button
again, the
Error Lamp
will twinkle 3 times.
( The density has set to High)
If all the mode have set, press the
MODE Button
and the
FEED Button
at the same time
after then release the buttons at the same time.
The printer will print out the mode status which has modified.
(PROTOCOL IrDA/ 38,400 BAUD/ 7 DATA BIT/ EVEN PARITY/ DENSITY HIGH)
If the status is not correct, please try it again according to the procedure.