DE-ASHING

 

Using the tool provided (shown in yellow) the grate is 

gently 

and 

NOT FORCEFULLY

 rotated clockwise to open 

and to de-ash and anti-clockwise to close and for the wood burning mode. 

 

GENTLE ROCKING

 movement will 

dislodge all but the largest clinkers through to the ashpan.  Too much riddling/poking can result in unburnt  fuel 
being emptied into the ash pan and should be avoided.  Any clinkers should be regularly removed from the fire 
bed. In the larger models there are two ashpans for ease of use. The ashpan should be emptied regularly before it 
becomes too full.  Use the operating tool to handle the ashpan, taking care not to spill the ashes as there may well 
be hot embers still glowing in the pan.

  Never allow ash to

 

accumulate in the ashpan

 so that it comes into  

contact with the underside of the grate as this  could  impede the movement of the grate link bar and therefore the 
movement of the grate bars and 

will  cause serious damage to the grate bars

.  Care should be taken that ash 

is cool before emptying into plastic bin liners.  If the grate bars will not rotate easily  

DO NOT FORCE

 them but 

investigate the possible cause, i.e. clinker or nails blocking movement or too much ash in ashpan and in the 
bottom of stove, and remedy as soon as possible.     
“Tippy” ash caddies are available from your local stockist to assist in the removal of ashes from the house. 

Diagram 6 

Diagram 6A 

Closed Open 

COMMISSIONING   

On completion of the installation and after allowing a suitable period of time for any fire cement or mortar joints 
to dry out, the stove should be cleaned using a soft dry cloth.  Check joints and seals.  The stove can then be lit 
and checked to ensure that smoke is taken from the appliance up the chimney and emitted safely.   

 
The customer should be advised on the use of the appliance.

 

On completion of the installation and commissioning please leave these operating instructions with the 
customer.   
 
HETAS LTD APPROVAL 
  

These appliances have been approved by HETAS Ltd as an intermittent operating appliance for burning the  
fuels listed on page 12.

 

Содержание Fox Fire

Страница 1: ...on and Guarantee Document A new era in clean effective multi fuel stoves Woodwarm Stoves Woodwarm Stoves Serial Number Also detailed on data plate located on the back of the stove Please quote when ma...

Страница 2: ...g Fuels for Burning on Fireview Stoves Daily Routine Maintenance and Servicing Operating Instructions for the Woodwarm Fireview Stoves How Clean Burn Works Initial Lighting Lighting To Achieve Cleanbu...

Страница 3: ...s wood 3 3 Mean Flue gas Temp o C wood 203 Efficiency ancit 82 1 Flue Gas mass flow g s ancit 2 2 Mean Flue gas Temp o C ancit 173 Weight Minimum Clearance From Inflammables without Woodwarm heat defl...

Страница 4: ...th when installing this appliance Health and Safety at Work It is the responsibility of the installer to comply with current Health and Safety Regulations and particular attention should be given to t...

Страница 5: ...t of your particular appliance Flues must be fitted in accordance with the manufacturers instructions and according to local Building Regulations If there is any doubt over the flue connec tion or the...

Страница 6: ...roof light dormer window or other opening Note 3 At least 1000mm above the top of the opening D within 2300mm of an adjoin ing or adjacent building whether or not beyond the boundary Note 3 at least...

Страница 7: ...7 Flue Outlet Configuration Register Plate Flexible Liner Rain Cap Tee With Removable Cap Woodwarm Rear Flue Adaptor Diagram 2 Minimum 4 5mtrs Flue Vent 600mm MAX of Single wall flue...

Страница 8: ...Fire cement and or a length of fireproof rope should be used to seal the join of the flue pipe and the flue spigot the joint between two flue pipes and where the flue pipe joins your chosen register p...

Страница 9: ...en contact with the stove body when the door is closed Your Fire Fox Stove has a door handle shown below in red to make it easier and safer to use your stove Use the heat resistant glove provided to o...

Страница 10: ...outer glass panel furthest from the fire is mounted on fibre glass ladder rope which should surround all the edges diagram 5 Caution is required when replacing this glass panel as the ladder rope has...

Страница 11: ...use serious damage to the grate bars Care should be taken that ash is cool before emptying into plastic bin liners If the grate bars will not rotate easily DO NOT FORCE them but investigate the possib...

Страница 12: ...et wood is pointless It produces far less heat maybe as little as 10 of that of dry wood Treat any bought in wood as wet unless its history is known Do not burn wet wood with solid fuel as a very aggr...

Страница 13: ...The paint used is a durable heat proof paint It is as a consequence porous and is not waterproof Before re lighting the stove after a long period out of use check that all flue ways are clear of obst...

Страница 14: ...t builds an Air Curtain over the glass and prevents all but a little of the normal tar de posits from condensing on the glass of the stove and causes all but a small proportion to be burnt in secondar...

Страница 15: ...f the stove to the rear drag any unburnt fuel to the front and add new fuel to the rear Try and keep the fuel at least 25mm from the door glass when the door is closed and repeat the procedure in B Fo...

Страница 16: ...stove to reach operating temperature before closing air controls FAULT FINDING A Stove smokes on lighting or when fire door is opened Flue ways blocked sweep chimney and flue Baffle incorrectly fitte...

Страница 17: ...se instructions or does not comply with current building regulations and any regional legislation in force at the time Metal Developments Ltd does not guarantee the onsite assembly installation or ope...

Страница 18: ...mber INSTALLERS DETAILS Name Address Phone Number HETAS Registration Number SPARE PARTS Use only Metal Developments Ltd approved replacement parts 14mm Main Fire Door Rope State model 14mm Ash Door Ro...

Страница 19: ...uk The National Association of Chimney Sweeps Unit 15 Emerald Way Stone Business Park Stone Staffordshire ST15 OSR Tel 01785 811732 www chimneyworks co uk The National Association Of Chimney Engineers...

Страница 20: ...20 30 09 09...

Отзывы: