7
Flue Outlet Configuration
Register Plate
Flexible Liner
Rain Cap
Tee With Removable Cap
Woodwarm Rear Flue Adaptor
Fig. 2
Minimum 4.5mtrs
Flue Vent
600mm
MAX
of
Single wall flue
Страница 1: ...tion and Guarantee Document A new era in clean effective multi fuel stoves Woodwarm Stoves Woodwarm Stoves Serial Number Also detailed on data plate located on the back of the stove door Please quote...
Страница 2: ...iew Stoves How Clean Burn Works Lighting Initial Lighting curing paint Stove Air Controls Running The Stove Extended Burning Things To Avoid Operation of the grate Daily Routine Maintenance and Servic...
Страница 3: ...82 9 82 9 Efficiency solid fuel 75 4 75 4 75 6 Co Emission 13 O2 wood 0 20 0 50 0 50 Co Emission 13 O2 solid fuel 0 28 0 28 0 16 Weight Minimum Clearance From Combustibles Rear 800 800 800 Side 500 50...
Страница 4: ...nts are used in the installation they should be installed in accordance with the manufacturers installation instructions and all wiring must comply with the current I E E regulations and the by laws o...
Страница 5: ...rofessional installer or the Building Inspector at your local council Whichever chimney option you choose to use DO NOT FORGET TO POSITION A CLEANING ACCESS if applicable in your flue and chimney that...
Страница 6: ...le rooflight dormer window or other opening Note 3 At least 1000mm above the top of the opening D within 2300mm of an adjoin ing or adjacent building whether or not beyond the boundary Note 3 at least...
Страница 7: ...7 Flue Outlet Configuration Register Plate Flexible Liner Rain Cap Tee With Removable Cap Woodwarm Rear Flue Adaptor Fig 2 Minimum 4 5mtrs Flue Vent 600mm MAX of Single wall flue...
Страница 8: ...d set screws should be used to reinforce the above joints where ap plicable Carefully remove any excess fire cement immediately to ensure no marking of the stove finish Replace the door by aligning it...
Страница 9: ...9 Rear Fire Board Side Fire Board Baffle in position FIRE BOARDS Fig 3 How to insert Baffle through doorway BAFFLE Fig 4 Fig 5...
Страница 10: ...10 LOGGUARD SOLID FUEL INFILLS Gem Blaze only Fig 6 a Fig 6 b Fig 7 a Fig 7b Fig 7 c...
Страница 11: ...is supplied with a heat resistant glove to operate the door han dle e t c when hot Turn handle to clockwise to open and turn anti clockwise to lock The door catches can be adjusted but ensure that th...
Страница 12: ...ash before the fuel is up to temperature and or wood fuel is too wet If a routine is established of hard burning on secondary air only for 20 minutes at each end of the day this will assist in keeping...
Страница 13: ...Smokeless fuel or dry wood Dry wood means that it has not more than 20 moisture content If these operating instructions are fol lowed correctly no significant smoke will be produced Burning wet 20 mo...
Страница 14: ...cool down prior Primary Air Control Under Grate Air Secondary Air Control Airwash Air STOVE AIR CONTROLS Fig 17 OPERATING INSTRUCTIONS Before lighting check with the installer that the work and check...
Страница 15: ...o a low or cool bed of embers as excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that a new fuel charge will ignite in a reasonab...
Страница 16: ...the closed position Using a small movement will dislodge all but the largest clinkers through to the ashpan Too much riddling poking can result in unburnt fuel being emptied into the ash pan and shou...
Страница 17: ...re boards and seals and replace if deteriorated Remove and clean over the baffle and clear flue ways more often if burning solid fuel A visit from the chimney sweep will remove the small amount of ash...
Страница 18: ...n If the above are closed then excess air may be entering from elsewhere Check if door glass and ash pit door rope seals are damaged or not seating Check all flue connections are airtight Check if flu...
Страница 19: ...ling in and returning the product Registration and Guarantee Form this will help maintain our records and assist us in identifying your stove in the unlikely event of any problem occurring and also wh...
Страница 20: ...er INSTALLERS DETAILS Name Address Phone Number HETAS Registration Number SPARE PARTS Use only Metal Developments Ltd approved replacement parts 14mm Main Fire Door Rope Door Glass Ladder Rope Door Gl...
Страница 21: ...k Stone Staffordshire ST15 OSR Tel 01785 811732 www chimneyworks co uk The National Association Of Chimney Engineers N A C E Ltd PO Box 849 Metheringham Lincoln Lincolnshire LN4 3WU Tel 01526 322555 F...
Страница 22: ...22 01 06 13 Version FSSE...