Woodwarm Stoves Fireblaze Скачать руководство пользователя страница 19

19 

THE WOODWARM STOVES GUARANTEE 

 
Metal Developments Ltd offer a five year guarantee which covers the main structure of the stove  
including the construction and quality of workmanship. 
 
In the unlikely event of any failure we will replace any defective part free of charge, labour cost  
excluded. 
 
This guarantee is invalid if the stove is not assembled, installed or operated as per these  
instructions or does not comply with current building regulations and any regional legislation in force 
at the time. 
 
Metal Developments Ltd does not guarantee the onsite assembly, installation or operation of the 
stove. Please seek advise from your stove supplier / installer for any relevant guarantees applicable 
to the installation. 
 
Metal Developments Ltd will not be held liable for any consequential or incidental loss, damage or 
injury, however caused. 
 
Claims under this guarantee should be first made through your Woodwarm Stove retailer. 
 
This guarantee is only applicable in the UK. 
 
Nothing in this guarantee shall effect your statutory rights. 
 

Exclusions 
 

The following consumable parts are not covered by this guarantee : - 
 

Swivel Fire Bars, Logguard, Baffle Plate, Operating Tool, Fire Boards, Glass Panels and Door 
Seals. 
 
Paint 

is also excluded from the guarantee as it will eventually deteriorate due to the normal working 

of the stove. 
 
Your assistance is requested by filling in and returning the product Registration and Guarantee 
Form, this will help maintain our records and assist us in identifying your stove in the unlikely event 
of any problem occurring and also when you need to order any spare parts. 
 

 

                      

      

IMPORTANT—READ THIS

 

 
                            

MAXIMUM  OPERATING TEMPERATURE

 

                                

 

The stove body is designed to run up to a maximum temperature not  exceeding 650F or 350C, beyond 
which damage can occur. 

We recommend the use of a stove thermometer available from your dealer. 

 

There are 3 possible causes for stoves over-heating :- 
1. 

Air controls, in particular the Primary ( under grate air), left  too far open for too long.  

You will hear 

the stove drawing too hard and the fuel bed will become White hot as will the surrounding metal of 
the stove. 

Do not leave the stove unattended  with air controls too far open. 

2.  

The fire door has been left open or the rope seal is worn, damaged or missing. This should be re-
placed if necessary or can be pulled out, adjusted and  easily re-placed. 

3. 

Excessive chimney draw (the minimum flue draft for nominal heat output is:-  not exceeding 0.15 
mbar  (0.06" water  gauge)).  If it is high use remedial action;  either the fitting of a flue stabiliser to 
the flue as close to the appliance as is aesthetically  possible, the fitting of  a flue damper in the chim-
ney, or a chimney cowl.  (Ask your dealer or contact us for details). 

Chipboard and other composite wood-type materials contain corrosive additives, as do sulphurous coal 
products 

especially when

 mixed with wet wood, these may etch and permanently damage the surface of the 

glass. 

Содержание Fireblaze

Страница 1: ...tion and Guarantee Document A new era in clean effective multi fuel stoves Woodwarm Stoves Woodwarm Stoves Serial Number Also detailed on data plate located on the back of the stove door Please quote...

Страница 2: ...iew Stoves How Clean Burn Works Lighting Initial Lighting curing paint Stove Air Controls Running The Stove Extended Burning Things To Avoid Operation of the grate Daily Routine Maintenance and Servic...

Страница 3: ...82 9 82 9 Efficiency solid fuel 75 4 75 4 75 6 Co Emission 13 O2 wood 0 20 0 50 0 50 Co Emission 13 O2 solid fuel 0 28 0 28 0 16 Weight Minimum Clearance From Combustibles Rear 800 800 800 Side 500 50...

Страница 4: ...nts are used in the installation they should be installed in accordance with the manufacturers installation instructions and all wiring must comply with the current I E E regulations and the by laws o...

Страница 5: ...rofessional installer or the Building Inspector at your local council Whichever chimney option you choose to use DO NOT FORGET TO POSITION A CLEANING ACCESS if applicable in your flue and chimney that...

Страница 6: ...le rooflight dormer window or other opening Note 3 At least 1000mm above the top of the opening D within 2300mm of an adjoin ing or adjacent building whether or not beyond the boundary Note 3 at least...

Страница 7: ...7 Flue Outlet Configuration Register Plate Flexible Liner Rain Cap Tee With Removable Cap Woodwarm Rear Flue Adaptor Fig 2 Minimum 4 5mtrs Flue Vent 600mm MAX of Single wall flue...

Страница 8: ...d set screws should be used to reinforce the above joints where ap plicable Carefully remove any excess fire cement immediately to ensure no marking of the stove finish Replace the door by aligning it...

Страница 9: ...9 Rear Fire Board Side Fire Board Baffle in position FIRE BOARDS Fig 3 How to insert Baffle through doorway BAFFLE Fig 4 Fig 5...

Страница 10: ...10 LOGGUARD SOLID FUEL INFILLS Gem Blaze only Fig 6 a Fig 6 b Fig 7 a Fig 7b Fig 7 c...

Страница 11: ...is supplied with a heat resistant glove to operate the door han dle e t c when hot Turn handle to clockwise to open and turn anti clockwise to lock The door catches can be adjusted but ensure that th...

Страница 12: ...ash before the fuel is up to temperature and or wood fuel is too wet If a routine is established of hard burning on secondary air only for 20 minutes at each end of the day this will assist in keeping...

Страница 13: ...Smokeless fuel or dry wood Dry wood means that it has not more than 20 moisture content If these operating instructions are fol lowed correctly no significant smoke will be produced Burning wet 20 mo...

Страница 14: ...cool down prior Primary Air Control Under Grate Air Secondary Air Control Airwash Air STOVE AIR CONTROLS Fig 17 OPERATING INSTRUCTIONS Before lighting check with the installer that the work and check...

Страница 15: ...o a low or cool bed of embers as excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that a new fuel charge will ignite in a reasonab...

Страница 16: ...the closed position Using a small movement will dislodge all but the largest clinkers through to the ashpan Too much riddling poking can result in unburnt fuel being emptied into the ash pan and shou...

Страница 17: ...re boards and seals and replace if deteriorated Remove and clean over the baffle and clear flue ways more often if burning solid fuel A visit from the chimney sweep will remove the small amount of ash...

Страница 18: ...n If the above are closed then excess air may be entering from elsewhere Check if door glass and ash pit door rope seals are damaged or not seating Check all flue connections are airtight Check if flu...

Страница 19: ...ling in and returning the product Registration and Guarantee Form this will help maintain our records and assist us in identifying your stove in the unlikely event of any problem occurring and also wh...

Страница 20: ...er INSTALLERS DETAILS Name Address Phone Number HETAS Registration Number SPARE PARTS Use only Metal Developments Ltd approved replacement parts 14mm Main Fire Door Rope Door Glass Ladder Rope Door Gl...

Страница 21: ...k Stone Staffordshire ST15 OSR Tel 01785 811732 www chimneyworks co uk The National Association Of Chimney Engineers N A C E Ltd PO Box 849 Metheringham Lincoln Lincolnshire LN4 3WU Tel 01526 322555 F...

Страница 22: ...22 01 06 13 Version FSSE...

Отзывы: