background image

Load Sharing Module 

Manual 02035 

 

 

 

26 

Woodward 

Engineering Services 

 
Woodward offers various Engineering Services for our products. For these services, 
you can contact us by telephone, by email, or through the Woodward website. 

 Technical 

Support 

 Product 

Training 

 Field 

Service 

 

Technical Support

 is available from your equipment system supplier, your local Full-

Service Distributor, or from many of Woodward’s worldwide locations, depending 
upon the product and application. This service can assist you with technical 
questions or problem solving during the normal business hours of the Woodward 
location you contact. Emergency assistance is also available during non-business 
hours by phoning Woodward and stating the urgency of your problem. 
 

Product Training

 is available as standard classes at many of our worldwide 

locations. We also offer customized classes, which can be tailored to your needs 
and can be held at one of our locations or at your site. This training, conducted 
by experienced personnel, will assure that you will be able to maintain system 
reliability and availability. 
 

Field Service

 engineering on-site support is available, depending on the product 

and location, from many of our worldwide locations or from one of our Full-
Service Distributors. The field engineers are experienced both on Woodward 
products as well as on much of the non-Woodward equipment with which our 
products interface. 
 
For information on these services, please contact us via telephone, email us, or 
use our website and reference 

www.woodward.com/support

, and then 

Customer Support

 
 

How to Contact Woodward 

 
For assistance, call one of the following Woodward facilities to obtain the address 
and phone number of the facility nearest your location where you will be able to 
get information and service. 
 

Electrical Power Systems 

Facility --------------- Phone Number 

Australia ----------- +61  (2) 9758 2322 
Brazil ------------- +55 (19) 3708 4800 
China ------------ +86 (512) 6762 6727 
Germany: 
 

Kempen --- +49 (0) 21 52 14 51 

 

Stuttgart ----- +49 (711) 78954-0 

India --------------- +91 (129) 4097100 
Japan -------------- +81 (43) 213-2191 
Korea--------------- +82 (51) 636-7080 
 
Poland -------------- +48 12 618 92 00 
United States----- +1 (970) 482-5811 

Engine Systems 

Facility --------------- Phone Number 

Australia ----------- +61  (2) 9758 2322 
Brazil ------------- +55 (19) 3708 4800 
China ------------ +86 (512) 6762 6727 
Germany: 
 
 

Stuttgart ----- +49 (711) 78954-0 

India --------------- +91 (129) 4097100 
Japan -------------- +81 (43) 213-2191 
Korea--------------- +82 (51) 636-7080 
The Netherlands - +31 (23) 5661111 
 
United States----- +1 (970) 482-5811 

Turbine Systems 

Facility --------------- Phone Number 

Australia ----------- +61  (2) 9758 2322 
Brazil ------------- +55 (19) 3708 4800 
China ------------ +86 (512) 6762 6727 
 
 
 
India --------------- +91 (129) 4097100 
Japan -------------- +81 (43) 213-2191 
Korea--------------- +82 (51) 636-7080 
The Netherlands - +31 (23) 5661111 
 
United States----- +1 (970) 482-5811 

 
You can also contact the Woodward Customer Service Department or consult our 
worldwide directory on Woodward’s website (

www.woodward.com/support

for the name of your nearest Woodward distributor or service facility. 
 
For the most current product support and contact information, please refer to the 
latest version of publication 

51337

 at 

www.woodward.com/publications

Содержание 9907-252

Страница 1: ...Installation and Operation Manual Load Sharing Module 0 5 4 5 Vdc Output 9907 252 Manual 02035 Revision B...

Страница 2: ...nce this copy was produced To verify that you have the latest revision be sure to check the Woodward website www woodward com pubs current pdf The revision level is shown at the bottom of the front co...

Страница 3: ...SETUP AND CALIBRATION 11 Introduction 11 Phasing Check 12 Phase Correction Procedure 13 Load Gain Adjustment 16 Droop Adjustment 17 Setting Droop for an Isolated Load 17 Setting Droop for an Infinite...

Страница 4: ...rials Wear cotton or cotton blend materials as much as possible because these do not store static electric charges as much as synthetics 3 Keep plastic vinyl and Styrofoam materials such as plastic or...

Страница 5: ...ufactured by Woodward and engines controlled with Woodward electronic controls or controls using other Woodward load sharing modules Description The Load Sharing Module provides isochronous and droop...

Страница 6: ...Load Sharing Module Manual 02035 2 Woodward Figure 1 2 Outline Drawing of Load Sharing Module...

Страница 7: ...Manual 02035 Load Sharing Module Woodward 3 Figure 1 3 Block Diagram of Load Sharing Module...

Страница 8: ...Load Sharing Module Manual 02035 4 Woodward...

Страница 9: ...Manual 02035 Load Sharing Module Woodward 5 Figure 1 4 Plant Wiring Diagram of Load Sharing Module...

Страница 10: ...these requirements when selecting the mounting location Adequate ventilation for cooling Space for servicing and repair Protection from direct exposure to water or to a condensation prone environment...

Страница 11: ...ircuit breakers in each of the PT lines to limit current to the LSM PT inputs to no more than 5 A In addition a 2 A fast acting fuse or circuit breaker must be provided in the 24 Vdc power supply line...

Страница 12: ...er insulation from both ends exposing the braided or spiral wrapped shield Do not cut the shield on the end nearest to the Load Sharing Module Cut off the shield on the end away from the unit 2 Use a...

Страница 13: ...leads to the terminals the Load Sharing Module contains internal burden which must be connected across the power source current transformers whenever the unit is running Ammeters may be installed on t...

Страница 14: ...t a 10 k 10 turn potentiometer to terminals 26 CW 27 wiper and 28 CCW Use 0 5 mm 20 AWG or larger shielded wire and connect the shield to the closest chassis screw Do not connect the potentiometer end...

Страница 15: ...manufacturer s instructions Adjust the engine for rated speed Apply full load to the generator set The most accurate calibration is made at full load However if it is not possible to run the generator...

Страница 16: ...the engine and apply full load to the generator set 12 Using a dc voltmeter measure the load signal at terminals 22 and 23 Adjust the load gain potentiometer to give a 6 Vdc load signal If 6 Vdc is n...

Страница 17: ...completed all three CTs are connected to the proper CT inputs on the Load Sharing Module with the correct polarity and are now labeled with their correct designations The procedure for correcting phas...

Страница 18: ...emergency shutdown when starting the engine turbine or other type of prime mover to protect against runaway or overspeed with possible personal injury loss of life or property damage 6 Start the engin...

Страница 19: ...load 24 Measure the load signal voltage between terminals 22 and 23 and record this voltage 25 Shut down the generator set 26 Remove the phase A CT wires from terminal 8 and 9 and connect the wires to...

Страница 20: ...et down and reverse the phase C wires on the CT input terminals 46 Start the engine and apply full load 47 Measure the load signal voltage between terminals 22 and 23 and record this voltage 48 Shut d...

Страница 21: ...three volts in cases of extremely poor system dynamics Droop Adjustment Droop is usually expressed as a percentage Droop percentage is calculated by dividing the difference between the no load speed...

Страница 22: ...entiometer fully clockwise for maximum droop 4 Synchronize the generator with the bus and parallel it with the bus 5 Increase the speed setting potentiometer to the position marked in step 2 increasin...

Страница 23: ...sensor circuit senses current amplitude and produces a load signal proportional to the current amplitude times the power factor The potential input comes from potential transformers PTs and the curre...

Страница 24: ...ed system with two or more generator sets paralleled if isochronous speed control is required one of the generator sets must be running in the isochronous constant speed mode This generator set mainta...

Страница 25: ...eed while applying load If droop occurs near the full load point only it is possible the engine is not producing the horsepower called for or is being overloaded Faulty engine control Disconnect the L...

Страница 26: ...e engine control or the engine Unequal speed settings Be sure the speed settings of all off line units at no load are identical Adjust as necessary Resynchronize Unequal load gain voltages Check that...

Страница 27: ...nt system documentation for details Woodward Business Partner Support Woodward works with and supports a global network of independent business partners whose mission is to serve the users of Woodward...

Страница 28: ...e of a scheduled outage to request a replacement control unit If the unit is available at the time of the call it can usually be shipped out within 24 hours You replace your field control unit with th...

Страница 29: ...erials when returning a complete control protective caps on any connectors antistatic protective bags on all electronic modules packing materials that will not damage the surface of the unit at least...

Страница 30: ...with which our products interface For information on these services please contact us via telephone email us or use our website and reference www woodward com support and then Customer Support How to...

Страница 31: ...s steam etc Rating Application Control Governor Information Please list all Woodward governors actuators and electronic controls in your system Woodward Part Number and Revision Letter Control Descrip...

Страница 32: ...op Switch The external droop switch is to be wired in series with the auxiliary circuit breaker contact between terminals 13 and 14 Droop mode is selected when either the droop switch or the auxiliary...

Страница 33: ...lse Installation Overvoltage Category Category III Air Quality Pollution Degree 2 DIMENSIONS Linear maximum Length 273 6 mm 10 77 in Width 214 1 mm 8 43 in Height 59 2 mm 2 33 in Weight 1397 g 49 3 oz...

Страница 34: ...Load Sharing Module Manual 02035 30 Woodward...

Страница 35: ......

Страница 36: ...t Drake Road Fort Collins CO 80525 USA Phone 1 970 482 5811 Fax 1 970 498 3058 Email and Website www woodward com Woodward has company owned plants subsidiaries and branches as well as authorized dist...

Отзывы: