505E Digital Governor 

Manual 85018V1 

 

 

 

vi 

Woodward 

Warnings and Notices 

 

Important Definitions 

This is the safety alert symbol. It is used to alert you to potential 
personal injury hazards. Obey all safety messages that follow this 
symbol to avoid possible injury or death. 

 

DANGER

—Indicates a hazardous situation which, if not avoided, will result 

in death or serious injury. 

 

WARNING

—Indicates a hazardous situation which, if not avoided, could 

result in death or serious injury. 

 

CAUTION

—Indicates a hazardous situation which, if not avoided, could 

result in minor or moderate injury. 

 

NOTICE

—Indicates a hazard that could result in property damage only 

(including damage to the control). 

 

IMPORTANT

—Designates an operating tip or maintenance suggestion. 

 

 

 

Overspeed / 

Overtemperature / 

Overpressure 

The engine, turbine, or other type of prime mover should be 
equipped with an overspeed shutdown device to protect against 
runaway or damage to the prime mover with possible personal injury, 
loss of life, or property damage. 

The overspeed shutdown device must be totally independent of the 
prime mover control system. An overtemperature or overpressure 
shutdown device may also be needed for safety, as appropriate. 

 

 

 

Personal Protective 

Equipment

 

The products described in this publication may present risks that 
could lead to personal injury, loss of life, or property damage. Always 
wear the appropriate personal protective equipment (PPE) for the job 
at hand. Equipment that should be considered includes but is not 
limited to: 

 

Eye Protection 

 

Hearing Protection 

 

Hard Hat 

 

Gloves 

 

Safety Boots 

 

Respirator 

Always read the proper Material Safety Data Sheet (MSDS) for any 
working fluid(s) and comply with recommended safety equipment.

 

 

 

 

Start-up

 

Be prepared to make an emergency shutdown when starting the 
engine, turbine, or other type of prime mover, to protect against 
runaway or overspeed with possible personal injury, loss of life, or 
property damage. 

 

 

 

Automotive 

Applications

 

On- and off-highway Mobile Applications: Unless Woodward's control 
functions as the supervisory control, customer should install a 
system totally independent of the prime mover control system that 
monitors for supervisory control of engine (and takes appropriate 
action if supervisory control is lost) to protect against loss of engine 
control with possible personal injury, loss of life, or property damage. 

 

 

Содержание 505E

Страница 1: ...roduct Manual 85018V1 Revision E Original Instructions 505E Digital Governor for Extraction Steam Turbines Volume 1 Manual 85018 consists of 2 volumes 85018V1 85018V2 Installation and Operation Manual...

Страница 2: ...ge including damage to the equipment Any such unauthorized modifications i constitute misuse and or negligence within the meaning of the product warranty thereby excluding warranty coverage for any re...

Страница 3: ...24 Introduction 24 Mechanical Data and Hardware Installation 24 CHAPTER 3 505E CONTROL DESCRIPTION 42 Introduction 42 Ratio Limiter Configurations 42 Speed vs Extr Adm Priority 49 Turbine Start 51 Tu...

Страница 4: ...DYN Key Screens 162 Stop Key Screens 163 Auxiliary AUX Key Screens 164 Remote Speed Bias RMT Key Screens 167 Cascade CAS Key Screens 170 Extraction Admission EXT ADM Key Screens 173 Alarms 176 Trips...

Страница 5: ...l RS 232 Communications 39 Figure 2 11 Typical RS 422 Communications 39 Figure 2 12 Typical RS 485 Communications 40 Figure 2 13a Preferred Multipoint Wiring 41 Figure 2 13b Alternate Multipoint Wirin...

Страница 6: ...17 ALARM Screen 177 Figure 5 18 TRIP Screen 178 Figure 5 19 Typical Response to Load Change 182 Figure 6 1 ASCII RTU Representation of 3 184 Figure 6 2 Modbus Frame Definition 185 Table 1 1 505s with...

Страница 7: ...Read Addresses 191 Table 6 7b Analog Read Addresses 192 Table 6 7c Analog Read Addresses 193 Table 7 8 Analog Write Addresses 193 Table 6 9a Control Status 194 Table 6 9b Control Status 195 Table 6 10...

Страница 8: ...mover control system An overtemperature or overpressure shutdown device may also be needed for safety as appropriate Personal Protective Equipment The products described in this publication may prese...

Страница 9: ...sed by improper handling read and observe the precautions in Woodward manual 82715 Guide for Handling and Protection of Electronic Controls Printed Circuit Boards and Modules Follow these precautions...

Страница 10: ...B C D T3B at 60 C Ambient rear enclosure provided T3C at 65 C Ambient rear enclosure omitted For use in Canada and the United States UL File E156028 Other International Compliance C Tick ACA RSM Decl...

Страница 11: ...er supply or control boards unless the area is known to be non hazardous RISQUE D EXPLOSION Ne pas raccorder ni d brancher tant que l installation est sous tension sauf en cas l ambiance est d cid men...

Страница 12: ...505E Digital Governor Manual 85018V1 x Woodward...

Страница 13: ...al 85017 describes the 505 Digital Governor for steam turbines without extraction pressure control Part Number Options Part Number Power 9907 165 HVAC 180 264 Vac 9907 166 AC DC 88 132 Vac or 90 150 V...

Страница 14: ...sous tension sauf en cas l ambiance est d cid ment non dangereuse La substitution de composants peut rendre ce mat riel inacceptable pour les emplacements de Classe I applications Division 2 ou Zone...

Страница 15: ...g is defaulted to zero but can be adjusted up to 3000msec using the debug mode MAIN AIx LATCH_DLY where x is the analog input number Added a tunable single pole filter LAG to each analog input Output...

Страница 16: ...ficed Modbus is a trademark of Schneider Automation Inc Additional Features The 505E also provides the following features First Out Trip Indication 5 total trip inputs Critical Speed Avoidance 2 speed...

Страница 17: ...and F4 can be used to enable or disable various functions of the control Control Outputs Two actuator outputs with linearization curves for the HP and the LP valve outputs Six 4 20 mA outputs for mete...

Страница 18: ...505E Digital Governor Manual 85018V1 6 Woodward Figure 1 1b Overview of 505E Functionality...

Страница 19: ...Manual 85018V1 505E Digital Governor Woodward 7 Figure 1 1c Overview of 505E Functionality...

Страница 20: ...n act as either a control channel or as a limiting channel All three of these PID controllers have the option of utilizing an analog input signal to remotely position their setpoints Additional featur...

Отзывы: