Setting Up

Handling

Unpacking

Positioning

•  Use suitable means to move the unit;  

- For smaller items use two people 
- For large items a fork lift, pallet trolley or similar (the forks should reach completely beneath the pallet)

•  Check the unit for damage before and after unpacking.  If unit is damaged, contact the distributor and manufacturer
•  Should any item have physical damage, report the details to the freight company and to the agent responsible for the dispatch within 

seven (7) days of receipt.  No claims will be accepted or processed after this period

•  The unit is supplied fully assembled
•  Remove all protective plastic film, tapes, ties and packers before installing and operating
•  Clean off any remaining residue from the interior/exterior of the unit using a clean cloth dampened with warm soapy water

•  When moving the unit, ensure the cabinet is upright at all times 
•  When positioning the unit, avoid direct sunlight, warm drafts and heated areas for the unit to maintain the normal operating 

temperature

•  Do not position the unit in: 

  - Wet areas 
  - Near heat and/or steam sources 
  - Near flammable substances

•  Ensure the unit is positioned on a level surface to allow all the condensation to properly burn off and prevent the burn off tray 

overflowing

•  Allow an air gap between the unit and other objects or surfaces.  A minimum gap of 100mm from all sides is recommend for normal 

operational use (if the unit is near any heat sensitive material we suggest you allow additional space), example below

•  After positioning the unit, allow the refrigeration gas to settle for at least 2 hours before switching ON
•  When installing into cabinetry sufficient ventilation must be included, to allow cold airflow into the unit and hot air to exhaust

•  Please consult national and local standards to ensure that your unit is positioned in accordance with any existing requirement

WARNING

Improper installation, adjustments, alterations, service or 

maintenance can cause property damage, injury or death.

Installation

Содержание W.CFSS.23

Страница 1: ...2020 Models W CFSS 23 W CFSSN 23 W CFSS 24 W CFSSN 24 W CFSS 25 W CFSSN 25 W CFSS 26 W CFSSN 26 SPECIFICATION INSTALLATION AND OPERATION MANUAL READ ALL INSTRUCTIONS BEFORE USE Cold Food Displays Self...

Страница 2: ...Page Intentionally Left Blank Page 1 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 3: ...Electrical Connection 7 Information Plumbing Connections 7 Information Refrigeration 7 Specification Technical Specification 8 W CFSS xx W CFSSN xx Operation Initial Start up Operation 9 Controller I...

Страница 4: ...red to persons units or others due to abuse and misuse of this unit in regards to installation removal operation servicing or maintenance or lack of conformity with the instructions indicated in this...

Страница 5: ...objects to remove ice from the unit If any fault is detected refer to troubleshooting The manufacturer declines any liability for damages to persons and or things due to an improper wrong and or unre...

Страница 6: ...otice www stoddart com au www stoddart co nz IMPORTANT This unit is not designed to cool down products it only maintains them at the controlled 2 C 5 C CAUTION This unit includes refrigeration compone...

Страница 7: ...oving the unit ensure the cabinet is upright at all times When positioning the unit avoid direct sunlight warm drafts and heated areas for the unit to maintain the normal operating temperature Do not...

Страница 8: ...oard Attach a yellow CAUTION DO NOT OPERATE tag This must be performed where relevant unless the procedures specify otherwise FAILURE TO DO SO MAY RESULT IN ELECTRIC SHOCK WARNING Notes If the supply...

Страница 9: ...d Specifications Model W CFSS23 W CFSS24 W CFSS25 W CFSS26 Height 787mm 787mm 787mm 787mm Width 1070mm 1400mm 1720mm 2050mm Depth 800mm 800mm 800mm 800mm Refrigerant R507A R507A R507A R507A Power 0 94...

Страница 10: ...it After 45 minutes check the cabinet temperature has reached 2 C 5 C Leave the unit to operate for 1 2 hours to remove any fumes or odours Clean the whole unit including the shelves before placing in...

Страница 11: ...return to the room temperature display KEY COMBINATIONS 1 Push and immediately release the SET key the display will show the set point value 2 Push and immediately release the SET key or wait 5 second...

Страница 12: ...as this can cause corrosion After treatment wash with warm not hot soapy water and dry thoroughly Thoroughly wipe the surfaces dry after cleaning DO NOT let water pool on the unit Check crevices and f...

Страница 13: ...l check crevices and folds 1 Clean the glass with a glass cleaner or warm not hot soapy water and a sponge 2 Using a squeegee remove all water from the glass Display Glass Periodic cleaning of the con...

Страница 14: ...s ON Power switch is in the Off position O Change the power switch to the ON position Power Point is faulty T Arrange a qualified Technician to repair the power point Refrigeration circuit board s is...

Страница 15: ...their local metal recycling centre to collect the remaining cabinet shelves etc There may be special requirements or conditions Information on the disposal of refrigeration appliances can be obtained...

Страница 16: ...Zealand Business Number 6837694 New Zealand Sales Tel 0800 79 1954 Email sales stoddart co nz Service Spare Parts Tel 0800 935 714 Email service stoddart co nz Email spares stoddart co nz www stoddar...

Отзывы: