Operation
Troubleshooting
Task Type - (O) = Operator
(T) = Technician Task
Problem
Possible Causes
Task
Possible Corrective Action
Unit won’t turn on
Unit is not plugged into a
suitable power point
O
Plug unit in
Power switch is in the “Off”
position
O
Change the power switch to the “ON” position
Power Point is faulty
T
Arrange a qualifi ed Technician to repair the power
point
Unit is overheating
Airfl ow blockage
O
Clear dirt / dust from fan guard and/ or clear all air
vents around the unit of any obstructions
Fan not working
T
Replace fan
Unit is not heating
Elements not working
T
Replace Elements as required
Temp switch / Computer board
not working
T
Replace switch / Computer board
(whichever is applicable)
Product is burning
Conveyor too slow
O
Adjust speed settings as required
Temperature set too high
O
Adjust temperature settings as required
Product is undercooked
Conveyor is too fast
O
Adjust speed settings as required
Temperature is set too low
O
Adjust temperature settings as required
Unit not turning off once timer
has fi nished
“On Continuous” switch is
activated
O
Deactivate “On Continuous” switch
WARNING!
Technician tasks are only to be completed by qualifi ed service