3. INSTALLATION (MECHANICAL)

3.1  

It is recommended that suitable safety guards form part of the installation wherever necessary.

3.2  

 We recommend that an air filter is fitted within the ductwork to reduce the accumulation of dirt on the fan 
impeller. An excessive build up of dirt could lead to imbalance of the impeller and vibration problems.

3.3  

 Where the product is delivered packaged, the packaging must be considered as a protective device only, 
and must not be used as a lifting aid unless otherwise indicated. During lifting all personnel must be clear 
of the area below the suspended fan.

3.4  

 An airflow indication arrow is shown on the fan nameplate. Sharp bends in the ductwork close to the 
fan must be avoided. Adequate room must be allowed round the fan for safe inspection and future 
maintenance, and the environment must be safe for both the fan, and for personnel.

3.5  

 Care must be taken to ensure that during extremes of wet and windy weather any ingress of water 
through the fan will not reach sensitive or hazardous areas within the building.

3.6  

 The component parts of the product, including anti-vibration mounts, flexible connectors (and their clips), 
weather proofing, platforms, supported drop rods and chains etc (if fitted), must be fully aligned before 
being bolted together so that no distortion or stress is placed on the equipment.

3.7  

 A minimum of 8 x M8 bolts, with the correct torque applied, must be used to secure the fan into position. 
The final position of the fan must be strong and rigid enough to take the weight of the fan and any other 
weight applied during installation.

3.8  

 Lagging should be applied between the box fan and silencer, around the connecting joint, to ensure 
maximum acoustic damping.

3.9  

 The product can be slightly tilted (to a maximum of 10 degrees) when used externally so that water runs 
off lid.

Fig.1

Содержание DASHIO EC TWINBOX

Страница 1: ...EC BOX FAN Safety Installation Operation and Maintenance Instructions...

Страница 2: ...IG 5 CONNECTION DIAGRAM EC BOX FAN AND IFAN CONTROLLER 8 10 INSTALLATION EXAMPLES 9 FIG 6 FLOOR MOUNTED ALL SIZES CORRECTLY MOUNTED 9 FIG 7 CEILING MOUNTED SPIGOT SIZES 125 150 200 AND 250MM ONLY CORR...

Страница 3: ...ntacted and supplied with full fan nameplate details before any repair work is undertaken 2 HANDLING STORAGE 2 1 On receipt of the product we recommend that it is checked against what was ordered Befo...

Страница 4: ...ment must be safe for both the fan and for personnel 3 5 Care must be taken to ensure that during extremes of wet and windy weather any ingress of water through the fan will not reach sensitive or haz...

Страница 5: ...e a danger and cause injury If there is any doubt that a safe and reliable installation of the fan can be assured Woods Air Movement or their representative should be contacted for advice See section...

Страница 6: ...e attempted before switching off and completely isolating the product and its controls from all electrical supplies Also allow the rotating parts of the fans to come to rest and the motors to cool 6 2...

Страница 7: ...o iFan manual 7 1 6 Three phase units also have additional MCB protection to each motor and a separate MCB that provides a single phase supply to the controls circuit These are found in a separate enc...

Страница 8: ...I M N I S N O I S N E M I D L L A K U D Z 5 4 O C X E S S E R E T S E H C L O C Y A W L A I X A 5 5 5 2 2 2 6 0 2 1 0 4 4 e n o h p e l e T 7 7 7 2 2 2 6 0 2 1 0 4 4 x a F K S A T B U O D N I F I C L...

Страница 9: ...rectly Mounted IMPORTANT NOTE When mounting on the ceiling in the normal position please ensure suitable drop rods are used Fig 8 Ceiling Mounted Inverted Spigot Sizes 125 150 200 and 250mm only Corre...

Страница 10: ...l Vertical Air Flow Up Sizes 125 150 200 and 250mm Only Correctly Mounted Fig 10 Wall Mounted Vertical Wall Mounted Vertical Air Flow Down All Sizes Incorrectly Mounted Fig 11 Wall Mounted Horizontal...

Страница 11: ...11 NOTES...

Страница 12: ...try application experience The widest range of Air Movement and Ventilation products in the market and strong market presence with over 100 years of experience and manufacturing of products guarantees...

Отзывы: