background image

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

R

WOODBRIDGE 

10

R

WOODBRIDGE 

 CAUTION 

 DANGER 

IMPORTANT  SAFETY  INSTRUCTIONS

 Indicates that failure to follow the instruction may cause body injury or 
 property damage. 

GROUNDING INSTRUCTIONS

 Improper use of the grounding plug can result in a risk of electric shock. 

SAVE THESE INSTRUCTIONS

1. Do not install or use the product in wet places as steam room etc.This product must be     
    connected to properly grounded power outlet socket.
2. It is recommended to use water-proof electrical outlet which should be lnstalled in the place 
    where is not easily got wet. 
3. This product should be used with AC 110V-120V,50/60Hz electrical current only,load current     
    is at least 15A. P ower plug must be equipped with ground fault circuit interrupter or ground     
    fault electrical leakage protector or similar high sensitive, rapid type leakage switch    
    (Rated sensitive current under 6mA).
4. When it thunders,it is strongly recommended to pull out the power plug.
5. Do not stand on ceramic toilet.
6. Ceramic toilet must install floor fixing bolt.
7. Do not stand on product unit,seat and cover.
8. Do not lean against the seat cover when using the product,to avoid damage.
9. This product is equipped with soft-closing seal cover.Heavy pressing or pushing may damage 
    the soft-closing damper. 
10. Do not use lacquer thinner,petrol,liquid medicine,detergent,insecticide,toilet cleanser and      
    scrubbing brush to clean the product.
11.Exposure to direct sunlight is prohibited.
12.Only use tap water or potable water;otherwise it may cause chafing.
13.Do not connect water supply to heater outlet.Make sure inlet water temperature at 3~35

Û&

14.When the room temperature is under zero degree,please dry up the water tank,to avoid 
     freezing. 
15.Raise rest room temperature to prevent the toilet from damage due to freezing.
16.When move the product from cold or wet environment into normal room temperature,wait for     
     2 hours until the condensation water is fully volatilized.Doing so can prevent the product from     
     electrical short-circuit.
17.When not using the product over three(3) days,drain the water out of the container and pull      
     the elelctrical plug from the wall outlet.
18.Stop using the product and shut off the power when product malfunctions,please contact the      
     service people for professional service.

This product should be grounded. In the event of an electrical short circuit, grounding reduces 
the risk of electric shock by providing an escape wire for the electric current. This product is 
equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged
into an outlet that is properly installed and grounded.

If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to
either flat blade terminal. The wire with insulation having an outer surface that is green with or
without yellow stripes is the grounding wire.
This product is factory equipped with a specific electric cord and plug to permit connection to a
proper electric circuit. Make sure that the product is connected to an outlet having the same
configuration as the plug. No adapter should be used with this product. Do not modify the plug
provided — if it will not fit the outlet, have the proper outlet installed by a qualified electrician. If
the product must be reconnected for use on a different type of electric circuit, the reconnection
should be made by qualified service personnel.

www.woodbridgebath.com

Содержание T-0022

Страница 1: ...R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R...

Страница 2: ...ave experience in the installation of products Limited warranty is void on any commercial installation We are not responsible for local code compliance for this product Building and plumbing codes may...

Страница 3: ...ION j 9 8 1 2 9 8 c z 2 9 3 2 3 23 j 6 329 32 8 329 8 9 3 2 3 23 j 9 1 9 8 3 32f9 38 29 32 j 9 23 29 8l9m 1 9 8 38 88 2 3 W j 9 8 1 2 9 8 2 9 6 89 3 89 6 9 68 38 3 6 32 9 3 2 3 www woodbridgebath com...

Страница 4: ...3 23 j 9 1 9 8 3 32f9 38 29 32 j 9 23 29 8l9m 1 9 8 38 88 2 3 W j 9 8 1 2 9 8 2 9 6 89 3 89 6 9 68 38 3 6 32 9 3 2 3 z 3 f 2 2 8 338 z 3 f 2 2 8 Side View Side View Back View 338 9 13 2 9 38 9 W 3 32...

Страница 5: ...holes and align bolts horizontaly See Figure 2 Figure 3 1638 2 V safety glasses must be worn by the installer and all bystanders Cover the floor with a soft close blanket Carefully turn the toilet on...

Страница 6: ...utor nor retailer is responsible for water damage or flood caused due to use of this product Under no circumstances We shall not be liable for any and all fees cost of installation reinstallation remo...

Страница 7: ...before adjustment Take out the lock nut and insert the push button into the tank cover Adjust the push button and lock the nut to make it well fixed in the tank The distance between the rod tail and v...

Страница 8: ...y clean prior to installation Check the fill valve and make sure that it does not have any damaged or missing parts 1 Press buckle and unscrew 2 Pull the valve upwards or press down to desired height...

Страница 9: ...e switch is turned on 2 Inlet valve float crashed against ceramic wall 3 Filter screen is clogged due to dirty water 4 Improper refill hose installation 1 Turn on inlet valve switch 2 Adjust inlet val...

Страница 10: ...st be switched off and water supply be shut off WARNING To reduce the risk of burns electrocution fire or injury to persons 1 Close supervision is necessary when this product is used by on or near chi...

Страница 11: ...the room temperature is under zero degree please dry up the water tank to avoid freezing 15 Raise rest room temperature to prevent the toilet from damage due to freezing 16 When move the product from...

Страница 12: ...power Safety device Drying device 6 different level adjustment 6 different level adjustment Over 4 M S Temperature sensor Temperature controller Thermal fuse Temperature controller Thermal fuse Groun...

Страница 13: ...AT PRE SSU RE POS ITIO N ENERGY SAVER Remote Control Panel Parts Base Plate Parts Water Supply Assembly Installation paperboard Installtion Manual Warranty Card Warranty Card Installtion Manual Instal...

Страница 14: ...Lid Side receiving window Water discharging cover Main unit disassembly button Remote control receiving window Power indicator Energy saving indicator Seat Drying device Base plate Night light Spray...

Страница 15: ...lates flat washers and bolt as per the drawing and tighten the bolts Bolt Washer Plastic plate Base plate Expansion nut Installation paperboard Note Unfold the installation paperboard align the paperb...

Страница 16: ...t out Installation Disassembly Note Before pulling out the washlet release hand from removal button Power line hole Water supply hole Note Connecting the water supply pipe Connect with smart unit wate...

Страница 17: ...witch Press protection switch NOTE CASE 1 Insert power plug into power socket NOTE If it s not an electric leakage protection plug insert power plug into power socket directly Water tank Checking the...

Страница 18: ...standby mode and then quick press Power button to restore functional mode 2 When people sit press Power button to stop the function of rear front cleaning or drying When no one sits press Power button...

Страница 19: ...wn the button located on the right side of main unit and pull out the seat Wipe the stain with a soft damp cloth 3 AfteX cleaning re install the seat back to main unit Do the following to clean the wa...

Страница 20: ...supply valve and remove water supply hose 2 Remove the filter Use the brush to clean the filter 3 Put the filter back into inlet after cleaning Then connect the water supply pipe When room temperature...

Страница 21: ...ntroller cannot display The wind temperature is setted on normal temperature level In standby mode or power save mode Power off Get stuck by impurities Do not sit in sensing area Reverse the polarity...

Отзывы: