�
�
�
�
�
�
�
�
PRE-INSTALLATION INFORMATION
FIREPLACE LOCATION
The following factors should be taken into consideration:
•
Clearance to side-wall, ceiling, woodwork, and windows. Minimum clearances to combustibles
must be maintained.
•
This fireplace may be installed along a wall, across a corner, or use an exterior chase.
See Figure 4
for suggested locations.
•
Location should be out of high traffic areas and away from furniture and draperies due to heat from appliance.
•
Never obstruct the front opening of the fireplace.
•
Do
not
install in the vicinity where gasoline or other flammable liquids may be stored.
•
Vent pipe routing. See
Venting
section found in this manual for allowable venting configurations.
•
These units can be installed in a bedroom
or bathroom.
See National Fuel Gas Code ANSI Z233.1/NFPA 54 (current edition),
the U
niform Mechanical Code — (current edition), and Local Building Codes for specific installation requirements.
Figure 4 - Locating Gas Fireplace
A
Flat on Wall
B
Cross Corner
C
Island**
D
Room Divider*
E
Flat on Wall Corner*
F
Chase Installation
** Island (C) and room divider (D) installation is possible as long as the horizontal portion of vent system (X)
does not exceed
20
'. See
Installing Horizontal Termination Configuration
on pages 18 and 19.
clearance must be maintained from perpendicular wall and front of fireplace.
____
__
____
__
____
__
____
____
__
__
__
__
to opening
COVERING FACE
Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following
Figure 2
and the
chart below for your specific installation requirements.
See Figure 3 on Page 8
for firebox dimensions. The framing headers may
rest on the top of the firebox standoff.
The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height. When the firebox
is installed directly on carpeting, tile, or other combustible material, other than wood flooring, the firebox shall be installed on a
metal or wood panel extending the full width and depth of the enclosure.
WARNING
IMPORTANT:
The following must be taken into consideration if
you decide to cover over the fireplace face:
to expand and contract during operation.
5. PLEASE NOTE: Natural stone products may react to heat by discoloring or cracking. Spark Modern Fires is not responsible
for any damages due to covering materials used. If tiles are to be applied covering the fireplace face, a layer of cement board
"
"
Do not fill spaces around firebox with insulation
or other materials. This could cause a fire.
must be used as a substrate.
9
2. Minimum outside dimensions of the material over the facing are
Y
8
" Minimum
*
When you install your fireplace in (D) room divider or (E) flat on wall corner positions (Y), a minimum of
8"
1.
The covering
material
must
be
non
combustible, maximum 3/4" thick.
Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be
used, framing and finishing details, and whether any optional accessories (i.e. wall switch, or remote control) are desired.
Consult your local building code agency to ensure compliance with local codes, including permits and inspections.
50" x 53.5".
(see Figure 5).
Содержание DV36CV-E
Страница 41: ...41 ILLUSTRATED PARTS LIST 11 1 2 3 4 5 6 7 8 9 10 LOG SET P N M100513...
Страница 46: ...127 6...
Страница 47: ...127 6...