Woodbridge BID 02 Скачать руководство пользователя страница 3

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

R

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

WOODBRIDGE 

2

R

WOODBRIDGE 

 CAUTION 

 DANGER 

IMPORTANT  SAFETY  INSTRUCTIONS

 Indicates that failure to follow the instruction may cause body injury or 

 property damage. 

GROUNDING INSTRUCTIONS

 Improper use of the grounding plug can result in a risk of electric shock. 

SAVE THESE INSTRUCTIONS

1. Do not install or use the product in wet places as steam room etc.This product must be     

    connected to properly grounded power outlet socket.

2. It is recommended to use water-proof electrical outlet which should be lnstalled in the place 

    where is not easily got wet. 

3. This product should be used with AC 110V-120V,50/60Hz electrical current only,load current     

    is at least 15A. P ower plug must be equipped with ground fault circuit interrupter or ground     

    fault electrical leakage protector or similar high sensitive, rapid type leakage switch    

    (Rated sensitive current under 6mA).

4. When it thunders,it is strongly recommended to pull out the power plug.

5. Do not stand on ceramic toilet.

6. Ceramic toilet must install floor fixing bolt.

7. Do not stand on product unit,seat and cover.

8. Do not lean against the seat cover when using the product,to avoid damage.

9. This product is equipped with soft-closing seal cover.Heavy pressing or pushing may damage 

    the soft-closing damper. 

10. Do not use lacquer thinner,petrol,liquid medicine,detergent,insecticide,toilet cleanser and      

    scrubbing brush to clean the product.

11.Exposure to direct sunlight is prohibited.

12.Only use tap water or potable water;otherwise it may cause chafing.

13.Do not connect water supply to heater outlet.Make sure inlet water temperature at 3~35

˚C

14.When the room temperature is under zero degree,please dry up the water tank,to avoid 

     freezing. 

15.Raise rest room temperature to prevent the toilet from damage due to freezing.

16.When move the product from cold or wet environment into normal room temperature,wait for     

     2 hours until the condensation water is fully volatilized.Doing so can prevent the product from     

     electrical short-circuit.

17.When not using the product over three(3) days,drain the water out of the container and pull      

     the elelctrical plug from the wall outlet.

18.Stop using the product and shut off the power when product malfunctions,please contact the      

     service people for professional service.

This product should be grounded. In the event of an electrical short circuit, grounding reduces 

the risk of electric shock by providing an escape wire for the electric current. This product is 

equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged

into an outlet that is properly installed and grounded.

If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to

either flat blade terminal. The wire with insulation having an outer surface that is green with or

without yellow stripes is the grounding wire.

This product is factory equipped with a specific electric cord and plug to permit connection to a

proper electric circuit. Make sure that the product is connected to an outlet having the same

configuration as the plug. No adapter should be used with this product. Do not modify the plug

provided — if it will not fit the outlet, have the proper outlet installed by a qualified electrician. If

the product must be reconnected for use on a different type of electric circuit, the reconnection

should be made by qualified service personnel.

www.woodbridgebath.com

Содержание BID 02

Страница 1: ...ore installation and keep it available for future maintenance or reference Our company reserves the right of final interpretation for this manual The manual is subject to change without notice Custome...

Страница 2: ...wer plug must be switched off and water supply be shut off WARNING To reduce the risk of burns electrocution fire or injury to persons 1 Close supervision is necessary when this product is used by on...

Страница 3: ...the room temperature is under zero degree please dry up the water tank to avoid freezing 15 Raise rest room temperature to prevent the toilet from damage due to freezing 16 When move the product from...

Страница 4: ...e 200W High temperature preventer thermal fuse If Applicable 6 level adjustment Over 0 2m min Warm wind speed Warm wind temperature Heating power Safety device Drying device Technical Specification No...

Страница 5: ...protection plug Whole set of product Power cord Infrared receiver Nozzle baffle Nozzle The remote control Buffer Lid Components Name Seat Release button Drying baffle Water supply pipe Front cleaning...

Страница 6: ...ne step 1 Long press Stop Button to make the main unit enter standby mode press Stop Button again to make the main unit return to Operating mode In standby mode all functions are invalid by pressing a...

Страница 7: ...nut 4 Expansion nut 2 Manual including warranty card Remote control Remote control rack The remote control assembly Base plate assembly The filter assembly Certificate of quality Certificate of quali...

Страница 8: ...not put it in a place prone to water Install Base plate Toilet mounting holes IInstall Mounting Cardboard The black latch faces Forward Groove up Install the expansion nuts into the toilet mounting h...

Страница 9: ...Connect to the angle valve Connect to main unit Connect Tee joint to angle valve The original Tee joint should be removed Connect the inlet end of water supply pipe to Tee joint according to the above...

Страница 10: ...ge Turn the angle valve counterclockwise to adjust the opening to the maximum Tips when the valve is opened for the first time the angle valve handle has a large torque 2 Power Connection Insert power...

Страница 11: ...motor Maintenance of Main Unit Daily Maintenance 1 Turn off the power during maintenance of this machine 2 Wipe the dirty area with a soft cloth that is wrung out of water 3 After wiping please turn o...

Страница 12: ...e power 3 Remove the seat press current limiting shaft in the middle with a flat blade screwdriver then reinstall the seat and open the inlet valve 4 If there is still no water coming out after pressi...

Страница 13: ...retch out Remote control cannot display Malfunction of deodorization Caution The wind temperature is set in normal temperature level In standby mode or power saving mode Power off Get stuck by impurit...

Страница 14: ...INSTALLER S NAME PLUMBER CONTRACTOR LICENSE INSTALLER INFORMATION NOTES DATE OF INSTALL INSTALLER S NAME PLUMBER CONTRACTOR LICENSE INSTALLER INFORMATION Customer Service Phone 562 229 0088 Monday Fr...

Отзывы: