background image

Woodbridge Fireplace Inc. 

 INSTALLATION AND OPERATING INSTRUCTIONS

 

DIRECT VENT GAS FIREPLACE WITH ELECTRONIC 

IGNITION SYSTEM

Report # 

401-S-05-4

MODELS: (B,H)DV2000(N,P)

-

E,  (B,H)DV3000(N,P)

-

E

– Do  not  store  or  use  gasoline  or  other 

fl

ammable

vapors and liquids in the vicinity of this or any other

appliance.

– WHAT TO DO IF YOU SMELL GAS

department.

– Installation  and  service  must  be  performed

by  a  qualified  installer,  service  agency  or  the

gas supplier.

This  appliance  is  only  for  use  with  the  type  of  gas 

indicated  on  the  rating  plate.  This  appliance  is  not 

convertible for use with other gases,  unless a certified

kit is used. 

  

CONSUMER: Retain this manual for future reference.

 

INSTALLER: Leave this manual with the appliance. 

This  appliance  may  be  installed  in  an  aftermarket, 

permanently   located,   manufactured   home  (USA 

only) or  mobile  home  where  not  prohibited  by  local 

codes.

   WARNING: FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in 

serious injury, death, or property damage.

• Do not touch any electrical switch; do not use any

phone in your building.

• Do not try to light any appliance.

phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fi

re

WARNING: Improper installation, adjustment, alteration, 

services  or maintenance  can  cause  injury  or property 

damage.  Refer  to  this  manual.  For  assistance  or 

additional  information  consult  a  qualif

i

ed  installer, 

service agency or the gas supplier.  

CLOTHING  OR   OTHER  FLAMMABLE 

MATERIAL SHOULD NOT BE PLACED ON 

OR NEAR THE APPLIANCE.

YOUNG

 CHILDREN

 SHOULD

 BE 

SUPERVISED WHEN  THEY  ARE  IN  THE 

SAME  ROOM  AS THE APPLIANCE.

CHILDREN  AND ADULTS SHOULD BE 

ALERTED TO  THE HAZARDS OF HIGH 

SURFACE  TEMPERATURE AND SHOULD 

STAY  AWAY  TO  AVOID  BURNS  OR 

CLOTHING IGNITION.

DUE   TO   HIGH   TEMPERATURES, THE 

APPLIANCE  SHOULD  BE  LOCATED  OUT 

OF TRAFFIC AND AWAY FROM FURNITURE

AND DRAPERIES.

Leave the building immediately.

Immediately call your gas supplier from a neighbor's

Version française de ce manuel est disponible à partir du site WEB : www.

woodbridgefp

.com

French version of this Owners Manual is available at www.woodbridgefp.com

KEEP  THE  ROOM  AREA   CLEAR

 

AND 

FREE FROM  COMBUSTIBLE  MATERIALS, 

GASO

L

INE,  AND  OTHER  FLAMMABLE 

VAPORS AND LIQUIDS

.

Содержание BDV2000NE

Страница 1: ...any electrical switch do not use any phone in your building Do not try to light any appliance phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire WARNING I...

Страница 2: ...l Ceiling Installation 24 Installing Gas Piping to Fireplace Burner Warranty Back Cover 2 3 Flex Vent Pipe Installation 25 Fireplace Installation 27 Check Gas Type 27 System Location 27 Checking Gas P...

Страница 3: ...and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon...

Страница 4: ...least ten 10 hours the rst time you use it Place the fan switch in the OFF position during this time 4 and others may be susceptible to accidental contact burns A physical barrier is recommended if t...

Страница 5: ...ural Gas and Propane Installation Code CSA B149 1 in Canada 5 Figure 1 Fireplace LISTED VENTED GAS FIREPLACE HEATER Direct Vent type appliances draw all combustion air from outside of the dwelling thr...

Страница 6: ...that all listed parts have been received You should have the following Fireplace Firebox and Burner System Rock Wool Log Set ITEMS REQUIRED FOR INSTALLATION Tools Building Supplies Phillips Screwdriv...

Страница 7: ...n a platform of an appropriate height When the firebox is installed directly on carpeting tile or other combustible material other than wood flooring the firebox shall be installed on a metal or wood...

Страница 8: ...16 36 5 16 18 1 4 580 sq in BDV3000PE 37 22 33 5 16 36 5 16 18 1 4 580 sq in BDV2000NE 33 20 1 2 29 5 16 32 5 16 15 488 sq in BDV2000PE 33 20 1 2 29 5 16 32 5 16 15 488 sq in HDV2000PE 33 20 1 2 29 5...

Страница 9: ...due to heat from appliance Never obstruct the front opening of the fireplace Do not install in the vicinity where gasoline or other flammable liquids may be stored Vent pipe routing See Venting sectio...

Страница 10: ...e floor Use four 4 screws to attach fireplace to framing The side brackets are adjustable from 1 2 to 5 8 to accommodate different thickness of material SECURING FIREPLACE TO FLOOR OR FRAMING Figure 5...

Страница 11: ...ctions exactly can create a fire hazard The appliance cannot be installed on a carpet tile or other combustible material other than wood flooring If installed on carpet or vinyl flooring the appliance...

Страница 12: ...SHING MATERIAL NOTE Any remote wiring i e remote control wall switch and optional fan must be done prior to nal nishing to avoid costly reconstruction INSTALLATION INFORMATION Only noncombustible mate...

Страница 13: ...e attached to a chimney serving a separate solid fuel burning appliance Each gas appliance must use a separate vent system Do not use common vent systems WARNING Horizontal sections of this vent syste...

Страница 14: ...he attic additional pipe and elbows will be required You may use a chase with a vent termination with exposed pipe on the exterior of the house See Installing Vent System in a Chase below If pipe is e...

Страница 15: ...inlet to any other appliance 12 305mm minimum K Clearance to a mechanical air supply inlet 6 1829mm minimum L Clearance above a paved sidewalk or paved driveway located on public property 7 2133mm min...

Страница 16: ...intersection draw a vertical line to the bottom of the graph 3 Select the indicated dimension and position the fireplace in accordance with same Example If the vertical dimension from the floor of th...

Страница 17: ...f pipe and elbows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have three locking lugs indentations These...

Страница 18: ...imble over the vent pipe before connecting the horizontal run to the vent cap See Figure 16 6 Carefully move the fireplace with vent assembly attached toward the wall and insert the vent pipe into the...

Страница 19: ...locate the fireplace in such a way that minimizes the number of offsets and horizontal vent length The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplac...

Страница 20: ...number of 45 elbows permitted per side wall installation is two 2 These elbows can be installed in either the vertical or horizontal run For each 45 elbow installed in the horizontal run the length of...

Страница 21: ...w base of snorkel Install drain pipe Install window well not supplied Refill hole with 12 of coarse gravel leaving a clearance of approximately 4 below snorkel See Figure 21 3 Install vent system 4 En...

Страница 22: ...0 to a maximum of 8 2 5 m of vent pipe can be used between elbows See Figure 26 BDV HDV Series fireplaces allow for offsets This application will require that you first determine the roof pitch and u...

Страница 23: ...w connections are fully twist locked See Figure 13 page 17 Figure 27 Offset with Wall Strap and 45 Elbows Roof Flashing Wall Strap 45 Elbows Ceiling Firstop Figure 28 If area above is a room install f...

Страница 24: ...g Support Box Installation Figure 31 Installed Cathedral Ceiling Support Box CATHEDRAL CEILING INSTALLATION IMPORTANT Review all information on previous page before planning this installation Cathedra...

Страница 25: ...exhaust Q ty 2 pcs 18 18 Clamp and secure with screws Clamp and secure with screws Exhaust DuraVent Pro 46DVA GCL Co Linear Adapter Chimney Liner Termination DuraVent Pro 46DVA VCH High Wind Terminat...

Страница 26: ...ttach a High Wind Termi nation Cap 46DVA VCH to 46DVA GK Figure 33c Pulling On Figure 33d Chimney Excess Flex Vent Termination Termination Cap 46DVA VCH the excess flex vent see Figure 3 FLEX VENT PIP...

Страница 27: ...ming gas pressure to between 11 and 13 inches of water If you do not reduce incoming gas External Regulator 100 lb min Propane LP Supply Tank Vent Pointing Down When using copper or flex connectors us...

Страница 28: ...tem may not run properly Tee Joint Pipe Nipple Cap Approved Flexible Gas Line CSA Design Certi ed Equipment Shutoff Valve with 1 8 NPT Tap Sediment Trap Drip Leg Natural Gas From Gas Meter 5 W C to 10...

Страница 29: ...ew counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point Turn unit to high See Figure 34 After taking pressure reading be sure and turn captured screw clockwise firmly...

Страница 30: ...codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition and Canadian Electrical Code CSA C22 1 WARNING Label all wires before disconnecting when servicing...

Страница 31: ...Release two clamps on top of fireplace See Figure 36 2 Tilt glass frame out and lift glass frame up until it clears bottom channel of fireplace 3 Set glass frame aside Figure 36 Removing Glass Frame G...

Страница 32: ...of the burner Replace logs and check flame again Save left over rock wool to refresh when cleaning later Too much rock wool can disturb the flame and cause sooting on the glass or logs Figure 37 Plac...

Страница 33: ...log Rest front Y shape on burner as shown in Figure 42 IMPORTANT Avoid ports when placing logs on burner Figure 40 Placing Top Left Log 3 Figure 41 Placing Bottom Right Log 4 Figure 42 Placing Bottom...

Страница 34: ...3 Logs should now look like Figure 45 Figure 45 All Logs in Place Figure 43 Placing Top Right Log 6 Figure 46 Log Placement for DV2000 Only Rear Log 1 Bottom Left Log 2 Bottom Right Log 4 Bottom Cente...

Страница 35: ...ll be replaced with the manufacturer s barrier for this appliance Any safety screen guard or barrier removed for servicing the appliance must be replaced prior to operating the appliance STEP 1 Remove...

Страница 36: ...glass door with a 50 50 vinegar and water solution Any fingerprints left on the glass or the safety screen STEP 5 Secure the screen with the two nuts provided STEP 6 Hold the top louver with two hand...

Страница 37: ...ly to the DFC board please verify that the electrical connections illustrated parts list or mounted in adjacent wall Make sure that the remote receiver switch is in REMOTE middle position Initializing...

Страница 38: ...arity of the batteries and insert into the battery bay as indicated on the battery covel 2 Place the 3 posilion slider switch in the REMOTE position 3 Insert the end of a paper clip into the hole mark...

Страница 39: ...r will ignite A single beep from the receiver will confirm the command Turning OFF the Appliance 1 Press the ON OFF button 011 the transmitter The A single beep from the receiver will confirm the comm...

Страница 40: ...Override If the receiver or transmitter batteries are low or de pleted the appliance can still be turned on manually 1 Move the receivers three position slider to the ON position This will bypass the...

Страница 41: ...Figure 53 Burner Flame Appearance CLEANING AND MAINTENANCE BURNER PILOT AND CONTROL COMPARTMENT BURNER Inspect area around the injector Remove any lint or foreign material with a brush or vacuum Turn...

Страница 42: ...f the glass should be cleaned off using a nontoxic non corrosive non abrasive mild cleaning solution Simply apply an adequate amount to the glass and wipe off with a damp cloth After all maintenance h...

Страница 43: ...ower is attached to the insert bottom and back with Velcro To remove blower for servicing pull away from Velcro and disconnect wires FAN ASSEMBLY DIAGRAMS Speed Control Control Shaft Locknut Control K...

Страница 44: ...ind Vertical Termination 46DVA VCH 3 6 6 Pipe Length 46DVA 06 3 6 9 Pipe Length 46DVA 09 3 6 12 Pipe Length 46DVA 12 3 6 24 Pipe Length 46DVA 24 3 6 36 Pipe Length 46DVA 36 3 6 48 Pipe Length 46DVA 48...

Страница 45: ...A100024 A100023 A100024 A100025 3 Glass Frame Assembly 1 A100026 A100027 A100029 A100030 A100031 8 Safety Barrier 1 W100212P W100016P W100212P W100016P 45 4 T stat Blower 1 A100014 A100014 A100014 A1...

Страница 46: ...00518 M100504 M100511 3 Top Left Log 1 N A M100505 M100512 4 Bottom Right Log 1 M100519 M100506 M100513 5 Bottom Center Log 1 M100520 M100507 M100514 6 Top Right Log 1 M100521 M100508 M100515 7 Top Ce...

Страница 47: ...SIT Proflame parts used in your fireplace 472 Receiver 14 Pin Connector Pilot CPI IPI MODE 120 Vac INPUT 7 Vdc STABILIZED SUPPLY OUTPUT MOTOR IPI CPI RECEIVER DC SUPPLY SPLIT FLOW ON OFF TPTH TH DFC S...

Страница 48: ...ILLUSTRATED PARTS LISTS 43 8 5 7 11 4 6 10 2 7 4 9 12 3 1 48...

Страница 49: ...OSTAT BLOWER WITH SPEED CONTROL 1 6 H100142 H100142 ELECTRONIC CONTROL DFC BOARD 1 3 C100020 C100020 DUPLEX OUTLET 1 2 D100027 D100027 FAN CONTROL FACE PLATE 1 BDV HDV 2000NE BDV HDV 2000PE 9 H100018...

Страница 50: ...ONIC CONTROL DFC BOARD 1 3 C100020 C100020 DUPLEX OUTLET 1 2 D100027 D100027 FAN CONTROL FACE PLATE 1 15 H200001 H200001 GTM REMOTE CONTROL 1 45 BDV HDV 3000NE BDV HDV 3000PE 10 W100002 W100002 BURNER...

Страница 51: ...chamber Ensure that the glass is properly secure and latch Frequent pilot outage A Pilot flame may be too high or A Clean and adjust the pilot flame for maximum flame impingement The pilot and main A...

Страница 52: ...s not extend to 1 firebox burner assembly damage by accident neglect misuse abuse alterations negligence of others including the installation thereof by unqualified installers 2 the costs of removal r...

Отзывы: