background image

A.G.A. Design-Certified

Manual Shutoff Valve

With 1/8” NPT Tap

Cap    Pipe Nipple   Tee Joint

                 

Sediment  Trap

3” Minimum

CONNECTING TO GAS 

SUPPLY

Installation Items Needed

pliers

-

sediment trap

-

tee joints

-

pipe wrench

Installation must include a manual 

shutoff valve, union, and plugged 

1/8” NPT  tap.  Locate  NPT  tap 

within  reach  for  test  gauge  hook 

up.  NPT  tap  must  be  upstream 

from the appliance.

Apply pipe joint sealant lightly to 

male  threads.  This  will  prevent 

excess  sealant  from  going  into 

pipe. Excess sealant in pipe could 

result in a clogged burner injector.

Install sediment trap in supply line 

as shown below. Locate sediment 

trap  where  it  is  within  reach  for 

cleaning and trapped matter is not 

likely  to  freeze.  A  sediment  trap

CHECKING GAS 

CONNECTION

Test Pressures in Excess Of 

1/2 psi (3.5 kPa)

Test Pressures Equal To or

Less Than 1/2 psi (3.5 kPa)

WARNING:

  A  qualified 

service  person  must  con-

nect  appliance  to  gas  sup-

ply. Follow all local codes.

WARNING:

  Test  all  gas 

piping  and  connections  for 

leaks  after  installing  or 

servicing.  Correct  all  leaks 

at once.

WARNING:

 Never use an 

open  flame  to  check  for  a 

leak.  Apply  a  mixture  of 

liquid  soap and  water on all 

joints.

Bubbles  forming 

show  a  leak.  Correct  all 

leaks at once.

From Gas Meter 

(5” W.C. to 10.5” W.C.

      pressure)

The  appliance  and  its  individual 

shutoff  valve  must  be  discon-

nected from the gas supply piping 

system during any pressure testing 

of that system at test pressures in 

excess of ½ psi (3.5 kPa).

The  appliance  must  be  isolated 

from the gas supply piping system by

  closing   its   individual   manual 

shutoff  valve  during  any  pressure 

testing  of  the  gas  supply  piping  

system  at  test  pressures  equal  to  or 

less than ½ psi (3.5 kPa).

Approved Flexible

Gas 

Connector

IMPORTANT

 

Flexible Gas Connectors.

Before  installing  the  Outdoor 

 items listed bellow:

-

piping (check local codes)

-

sealant 

-

manual shutoff valve

-

adjustable (crescent) wrench or 

traps  moisture  and  contaminants. 

This  keeps  them  from  going  into 

If sediment trap is not installed or 

is installed wrong, unit may not  

run properly.

GAS CONNECTION

8

Log Set

, make sure you have all

Outdoor

 Log Set

 controls. 

 

 

CAUTION:

 Use only new, 

black  iron  or  steel  pipe. 

Internally  tinned  copper 

tubing  may  be  used  in 

certain  areas.  Use  pipe  of 

1/2"  diameter  or  greater  to 

allow  proper  gas  volume  to 

the Gas Log Set

.

 

If 

pipe is too

small, undue loss

 of pressure

will occur.

This  appliance  is  not  designed 
for   use  with  a  non-disposable, 
self-contained propane as  
supply system! Do not use a gas
hose to  connect the appliance 
to any gas supply. Use approved
 

Содержание GLO-18

Страница 1: ...as no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space as a camper tent car or home DANGER If you smell gas 1 Shut off gas to appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance and immediately call your gas supplier or fire department WARNING For Outdoor Use Only INSTALLER Leave this manual with the appliance CONSUMER...

Страница 2: ... 2 Specifications 5 Locating Your Fireplace 6 Burner Assembly Instructions 8 Lighting Instructions 12 Operating Instructions 14 To Turn Off Gas to Appliance 14 Cleaning and Maintenance 15 Troubleshooting 16 Illustrated Parts Breakdown Parts List 18 18 Log Set Installation 10 24 Log Set Installation 11 ...

Страница 3: ... completely before trying to assemble operate or Improper use of this unit can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning DANGER Carbon mo noxide poisoning may lead to death use with this Gas Log Set Gas Log Set Do not use this clothing or other flammable objects are less than 42 inches from the front top or sides of the Log Set of this L...

Страница 4: ... this appli ance or use of unauthorized components or accessory items will void the manu facturer s warranty and may result in a hazardous condition attached to the Gas Log set 4 SAFETY INFORMATION IMPORTANT the firebox specifications This outdoor gas log set is designed to be placed and operated inside a custom built NON COMBUSTIBLE FIREBOX See next page for kept clean 15 Installation and repair ...

Страница 5: ...let Gas Pressure MIN 5 0 w c 11 0 w c Manifold Pressure 3 5 w c 10 0 w c Inlet Gas Pressure MAX 10 5 w c 13 0 w c Ignition Manual with BBQ lighter Manual with BBQ lighter Ignition Manual with BBQ lighter Manual with BBQ lighter Heat Output Btu h 60 000 60 000 Heat Output Btu h 45 000 45 000 Orifice Size 26 42 Shipping Weight Lbs 125 125 Shipping Weight Lbs 150 150 ROBERTSHAW Valve Model 711 811 40...

Страница 6: ...ver Within a partial enclosure that includes an overhead cover and more than two walls the following shall apply At least 25 of the total wall area is completely open and At least 30 of the remaining wall area is open and unrestricted Within a partial enclosure that includes an overhead cover and no more that two walls IMPORTANT custom built NON COMBUSTIBLE FIREBOX See previous page for the firebo...

Страница 7: ...sure loss will occur if the pipe is too small CAUTION 1 2 NPT 2 Pointing the vent down protects it from freezing rain or sleet Figure 2 External Regulator with Vent Pointing Down 7 GAS CONNECTION Use proper gas type for the Log Set you are installing If you have conflicting gas type do not install fireplace See dealer where you purchased the Log Set for proper fireplace for your gas type or conver...

Страница 8: ...s Bubbles forming show a leak Correct all leaks at once From Gas Meter 5 W C to 10 5 W C pressure The appliance and its individual shutoff valve must be discon nected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve d...

Страница 9: ...joint with a soap and water solution 5 Test functionality of the Log Set burner see Operating Instructions before placing logs the media and the pilot is not blocked with loose pieces of glass Make sure the flame is tall steady and yellow Ignition time should not exceed 5 7 seconds Remove grate from the box and place onto the base with rear legs positioned inside of support brackets 7 DO NOT REMOV...

Страница 10: ...3 4 5 6 5 4 3 2 1 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specially approved with this appliance may result in property damage or personal injury GLO 18 LOG SET LOG PLACEMENT ...

Страница 11: ...11 24 LOG SET INSTALLATION 11 GLO 24 LOG SET 1 2 3 4 5 6 7 LOG PLACEMENT 1 2 3 4 5 6 7 ...

Страница 12: ...n D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING PILOT FOR THE FIRST TIME INITIAL LIGHTING Purge air from the supply line as follows Open main shutoff valve Unscrew main...

Страница 13: ...control body WARNING Never use an open flame to check for gas leak DANGER 1 STOP Read the safety information on previous page If the pilot does not stay lit repeat steps 1 and 2 If the pilot knob does not pop up when released STOP and immediately call service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF position and call your servic...

Страница 14: ...aintaining the pilot light Depress and turn knob to pilot position to keep burner off while Remote Position MAIN BURNER SWITCH REMOTE position It will take less than four 4 seconds for the burner to ignite Depress and turn the knob counterclockwise to the ON on remote control receiver beneath the base This switch allows you to knob Make sure the button is in the REMOTE position to operate the main...

Страница 15: ...t when the fireplace is in operation The pilot flame has two distinct flames one engulfing the thermopile and the other reaching to the main burner BURNER Inspect area around the injector Remove any lint or foreign material with a brush Turn off gas before servicing fireplace It is recommended that a qualified service technician perform these check ups at the beginning of each heating season WARNI...

Страница 16: ...h any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions Ifyoucannotreachyourgassupplier callthefiredepartment Pilot lights but flame goes out when control knob is released Burner does not light after pilot is lit 1 Press in control knob fully 2 After pilot lights keep control knob pressed in 30 ...

Страница 17: ...products while unit is running 2 Locate and correct all leaks see Check ing Gas Connections page 5 1 Locate and correct all leaks see Check ing Gas Connections page 5 2 Replace control valve 1 Locate and correct all leaks see Check ing Gas Connections page 5 Gas Log Set produces unwanted odors carpet etc 2 Gasleak SeeWarningstatement on previous page 1 Gasleak SeeWarningstatement on previous page ...

Страница 18: ...1 2 3 4 5 8 9 10 11 FOR PART DESCRIPTION 12 6 7 13 13 14 ILLUSTRATED PARTS LIST 18 SEE NEXT PAGE ...

Страница 19: ...0090 D300090 SUPPLIED 1 2 SHUTOFF VALVE 1 12 PCB R PCB R SKYTECH REMOTE RECEIVER 1 11 PCB PCB SKYTECH REMOTE CONTROL 1 9 D300098 D300098 1 2 X 12 FLARE GAS CONNECTOR 1 8 C100038 C100038 5 16 X 7 FLEX CONNECTOR 1 5 R100020 R200020 MAIN GAS VALVE 1 GLO 24 LOG SET NO GLO 24 N GLO 24 P DESCRIPTION 1 W200208 W200208 BURNER ASSEMBLY 1 2 F200220 F200220 BASE 1 3 W200210 W200210 GRATE 1 13 M100508 M100508...

Страница 20: ...igence of others including the installation thereof by unqualified installers 2 the costs of removal reinstallation or transportation of defective parts on the appliance or 3 incidental or consequential damage All service work must be performed by an authorized service representative This warranty is expressly in lieu of other warranties express or implied including the warranty of merchantability...

Отзывы: