1)
When selecting a location for your fi replace, ensure that the clearances are met.
2)
This appliance must be installed in an open-air situation with natural ventilation, without
stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind
and natural convection.
3)
Certain materials or items, when placed under or near the appliance, will be subjected to radiant
heat and could become damaged.
4)
Typically an outdoor space is not enclosed but, any enclosure in which the appliance is used
shall comply with one of the following:
An enclosure with walls on all sides, but at least one permanent opening at ground level and
no overhead cover.
Within a partial enclosure that includes an overhead cover and more than two walls, the following
shall apply:
•
At least 25% of the total wall area is completely open, and
•
At least 30% of the remaining wall area is open and unrestricted
Within a partial enclosure that includes an overhead cover and no more that two walls.
IMPORTANT
custom built NON-COMBUSTIBLE FIREBOX. See previous page for
the firebox specifications.
This outdoor gas log set is designed to be placed and operated inside a
LOCATING YOUR
OUTDOOR GAS FIREPLACE
.
If you are planing to locate your firebox inside of any outdoor structure (enclosure), please refer to the following.
6
LOCATING YOUR
FIREPLACE
30% or more in total of the remaining wall
area is open and unrestricted.
Open side at least 25% of total wall area
IMPORTANT: Minimum ambient air temperature for the
log set operation is 0°C (32°F)