background image

Installation and Operation Manual

Professional Series

Wood Fired Grill

Stand Mounted and Countertop Models

PROFESSIONAL SERIES GRILL

WS-PWG-5426

enhance your

food, home & lifestyle

with a Wood Stone Home Appliance

woodstonehome.com
[email protected]

tf. 800.578.6836
f.   360.734.0223

Wood Stone Corporation

1801 W. Bakerview Rd.
Bellingham, WA 98226 U.S.A.

An ongoing program of product improvement may require us to change specifications without notice. 

Doc no: M0325.00

Rev. November 2020

Содержание WS-PWG-5426

Страница 1: ...5426 enhance your food home lifestyle with a Wood Stone Home Appliance woodstonehome com info woodstonehome com tf 800 578 6836 f 360 734 0223 Wood Stone Corporation 1801 W Bakerview Rd Bellingham WA 98226 U S A An ongoing program of product improvement may require us to change specifications without notice Doc no M0325 00 Rev November 2020 ...

Страница 2: ...on 1801 W Bakerview Rd Bellingham WA 98226 U S A M0325 00 Rev November 2020 Table of Contents Professional Series Grill Installation and Operation Manual TABLE OF CONTENTS Professional Series Grill 3 Cautions Warnings 4 Specifications 7 Clearances 8 Installation 9 Grill Shelf Installation 10 Fuel Safety 11 Fueling the Grill 12 Maintenance 14 Fuelwood Facts 15 Replacement Parts 16 Limited Warranty ...

Страница 3: ...erview Rd Bellingham WA 98226 U S A M0325 00 Rev November 2020 Professional Series Grill INSTALLATION AND OPERATION MANUAL FOR THE WOOD STONE PROFESSIONAL SERIES GRILL STONE FIRED COOKING EQUIPMENT WOOD FIRED GRILL INCLUDING COUNTERTOP MODELS ADDITIONAL MANUAL COPIES AVAILABLE UPON REQUEST Professional Series Grill Installation and Operation Manual Shown with optional Stainless Steel Shelves and S...

Страница 4: ...iquids well away from this appliance when in use DO NOT USE PRODUCTS NOT SPECIFIED FOR USE WITH THIS APPLIANCE USE SOLID WOOD FUEL ONLY RETAIN THIS MANUAL FOR FUTURE REFERENCE Additional copies of this manual at woodstone corp com For prompt responses to service maintenance questions call us at 1 800 988 8103 WARNING Improper installation adjustment alteration service or maintenance can result in ...

Страница 5: ...CTION WITH ANY AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS iii DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE iv DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL v HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS FOR RESIDENTIAL USE TO BE INSTALLED ONLY OUTDOORS CLEARANCES TO COMBUSTIBLES...

Страница 6: ...installed and maintained in accordance with all applicable local codes and regulations In the absence of local codes relevant Na tional Codes shall be referred to When using the appliance out in the open beware that sparks and embers can become airborne in the course of operating the appliance To avoid risk of fire only operate the appliance in a safe area where sparks or embers cannot land on veg...

Страница 7: ...RPORATION 1801 W BAKERVIEW RD BELLINGHAM WA 98226 360 650 1111 WOODSTONE CORP COM PART NO WS PWG 5426 SIZE B REV 0 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF WOOD STONE CORPORATION ANY REPRODUCTION OR USE IN PART OR AS A WHOLE WITHOUT EXPRESS WRITTEN PERMISSION OF WOOD STONE CORP IS PROHIBITED 6 150mm 16 1 2 420mm 52 1 2 1330mm 1 30mm 1 2 3 4 A B C D 1 2 3 4 PART NO SIZE B T...

Страница 8: ...A MAJOR CAUSE OF APPLIANCE RELATED FIRES IS A FAILURE TO MAINTAIN REQUIRED CLEARANCES TO COMBUSTIBLE MATERIAL IT IS OF UTMOST IMPORTANCE THAT THIS APPLIANCE BE INSTALLED ONLY IN ACCOR DANCE WITH THESE INSTRUCTIONS SIDES ABOVE if installed under a suitable metal hood or masonry chimney The hood or chimney assembly should extend at least 12 inches beyond the outside perimeter of the grill to ensure ...

Страница 9: ...ns without notice DIMENSIONS ARE IN INCHES TOLERANCES LINEAR 1 2 10mm ANGULAR 2 UNLESS NOTED OTHERWISE 1 of 1 Seal bottom edge of flashing to counter using high temp silicone provided Seal any gap between the flashing and the charbroiler using the high temp silicone provided Using the hardware provided install the stainless steel flashing to the front and back of the charbroiler Install Sacrificia...

Страница 10: ... GRILL 1 The optional Broiler Shelf Stand is lowered onto the Professional Series Grill so that the legs slide over the side walls The broiler shelf must be re moved to install the stainless steel rain cover Allow shelf to cool before removing 1 of 1 INSTALL RACKS ONTO STAND 2 Place the Wire Cooking Rack Supports onto the upper or lower bottom supports 3 Place the lower Wire Cooking Racks onto the...

Страница 11: ...and handled in accordance with the recommendations outlined in NFPA 96 DISPOSAL OF ASHES Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on the ground well away from the combustible materials pending final disposal When the ashes are disposed by burial in soil or otherwise locally dispersed they shoul...

Страница 12: ...s out of the intense start up fire heat and to create working space 2 Using the Ash Shovel remove about 2 3rds of the fly ash Move ash and any live coals along the back center of the fire box The coals and ash will help start the new fire faster LUMP CHARCOAL AND WOOD FIRE 4 Stack 3 or 4 small pieces of wood in a conical tepee shape on top of any live coals towards the back of the fire box Ignite ...

Страница 13: ... Tool to distribute the coals in the firebox with about 3 deep in the back tapering to 1 1 2 deep in the front 8 To optimize heat and energy pull live coals forward out of the fire Do not pull wood with open flame forward Cooking over an open flame tends to burn fat making food taste bitter 6 6 8 8 7 7 MAINTAINING THE FIREBOX 7 Place two medium pieces of wood on either side of the center flame eve...

Страница 14: ...toring it inside of any structure CREOSOTE FORMATION AND NEED FOR REMOVAL If using any type of chimney hood or venting system above the appliance regular inspection and cleaning is required Any creosote buildup must be removed to reduce risk of fire When wood is burned slowly it pro duces tar and other organic vapors that combine with expelled moisture to form creosote The creosote va pors condens...

Страница 15: ... residue which accumulates on the flue lining and exhaust hood increasing the risk of fire Wood should be stored off the ground and out of the rain in an environment that allows good air circulation so the drying process can continue follow the recommendations in NFPA 96 for safe wood storage and handling practices Wet wood is the most common operational difficul ty associated with wood fired cook...

Страница 16: ...TED rogram of product improvement may require us to fications without notice 360 650 1111 www woodstone corp com DIMENSIONS ARE IN INCHES NCES LINEAR 1 2 10mm ANGULAR 2 UNLESS NOTED OTHERWISE a Desktop 001 5SFB_Mt_St_Helens_SFB_Floor_Mount 1 dft The drawing below indicates part numbers for the replaceable parts on all Mt St Helens models See table for specific model grate capacities and grate part...

Страница 17: ...acking due to expansion and contraction stress relief in the ceramic firebox 9 In the event that pressed log products of any type have been burned in the equipment 10 Damage resulting from the use of chemical cleaning products in the appliance as well as any damage from liquids or chemicals including water being poured or sprayed into the appliance If any oral statements have been made regarding t...

Страница 18: ...PG 18 OF 20 M0325 00 NOVEMBER 2020 This page left blank with intention ...

Страница 19: ...PG 19 OF 20 M0325 00 NOVEMBER 2020 This page left blank with intention ...

Страница 20: ... Free 800 578 6836 Fax 360 734 0223 woodstonehome com info woodstonehome com WOOD STONE CORPORATION 1801 W Bakerview Rd Bellingham WA 98226 USA An ongoing program of product improvement may require us to change specifications without notice ...