M0324.00 APRIL 2020
Traditional Series CE
Installation and Operation Manual
INSTALLATION CLEARANCES
THE FOLLOWING CLEARANCE INFORMATION APPLIES TO ALL
WOOD STONE TRADITIONAL SERIES OVENS
Please see
woodstone-corp.com
for floor loading information.
25mm (1") side clearance to
combustible building materials.
152mm (6") top clearance to
combustible building materials.
If enclosing the oven, any facade
materials 152mm (6") to either side
of the doorway and above must be
NON-COMBUSTIBLE.
Note:
0" side and top clearance to non-
combustible materials. However, the
respective clearances to combustibles
are transferred to those non-
combustibles.
152mm (6")
Combustible building material
Floor
Any facade wall 152mm (6") to either side of
the oven doorway and above
MUST
be of non-
combustible construction with no exceptions.
Gas-only models:
Suitable for installation
on combustible floors.
For gas/wood combination models
,
this oven is suitable for installation on
combustible floors. The minimum hearth
extension area to be covered with a non-
combustible floor surface must extend
914 mm (36") in front of and 762 mm (30")
to either side of the oven door opening.