PG
21
OF
36
M0324.00 APRIL 2020
Traditional Series CE
Installation and Operation Manual
RFG-IR-(W) OPERATION
DAILY OPERATION FOR RFG-IR-(W) MODELS
IMPORTANT:
If at any time you feel that the burner is not operating properly, TURN THE OVEN OFF
and call for service.
Before servicing, disconnect the electrical supply at the breaker and turn OFF the gas supply at the appliance’s individual gas
shutoff valve. In the event of a power failure, no attempt should be made to operate the oven.
DAILY STARTUP
Press the I/O button to start the oven. The radiant burner will ignite. The infrared Underfloor IR burner will ignite if the actual
floor temperature is below the Hearth Set Point temperature to which the controller is adjusted.
Green light
indicates the system is energized.
Green light
indicates the pilot flame for the radiant burner is lit.
Green light
indicates that the pilot flame for the Underfloor IR burner is lit.
This light will go OFF whenever the actual floor temperature is above the Hearth Set Point.
TURNING OFF THE OVEN
Push the I/O button on the controller to turn the oven OFF.
Both burners will go out and the digital readout on the controller will go out.
ADJUSTING THE RADIANT (DOME) FLAME
To adjust the radiant flame:
The radiant flame is always on (when the oven is operating) and can be adjusted to any flame
intensity between its highest and lowest setting. Simply turn the knob located to the lower left of the doorway, beneath the
mantle. This burner is the primary heat source for the oven. The infrared under floor burner will act as an assist, to maintain
desired floor temperatures during periods of high food production.
HOW TO READ FLOOR TEMPERATURE
The floor temperature is continuously displayed by the controller in the upper window. This reading is being taken by a
thermocouple about 25mm (1") below the floor surface, so the actual surface temperature may be different, and is best
measured using a non-contact (IR) thermometer.
Note:
The display will read “LO” when the temperature is below
38 °C (100 °F).
ADJUSTING THE FLOOR SET POINT
To adjust the oven’s thermostatic floor temperature setting, simply press the arrow button corresponding to the direction in
which you would like the setting to go. If the thermostatic Hearth Set Point is raised above the actual hearth temperature, the
underfloor IR burner should activate. It is only possible to program the floor’s thermostatic Hearth Set Point to temperatures
from 38 °C (100 °F) to 426 °C (100–800 °F). Once proper temperatures for your application have been established, there
should be little or no need to change the Hearth Set Point.
For additional information on temperature control, see the FLAME HEIGHT CONTROL section of this manual.
FOR MODELS APPROVED TO ALSO BURN WOOD
See the BURNING WOOD section of this manual for information on burning wood. Models listed to burn wood will have a -W
at the end of the model number.