UTILITIES SPECIFICATIONS
Gas
3/4 inch FNPT gas inlet
105,000 BTU/hr Natural Gas (NG)
OR
100,000 BTU/hr Propane (LP)
Maximum gas inlet pressure
34 mbar (1/2 psi or 14 inches W.C.)
Electrical
120 VAC, 2 A, 50/60 Hz
Optional: 240 VAC, 1 A, 50/60 Hz
All utility connections made on the back
of the oven control box. Remove front or
rear panel for access Use utility knockouts
(provided) to route gas and electrical
supplies. Refer to data plate when installing.
Venting
The Phoenix must be vented using an approved
chimney, or an exhaust hood constructed and installed
in accordance with all relevant local and national codes.
Remove round collar if venting with an exhaust hood
Side view
Rear view
Plan view
G
43"
1090mm
47 3/4"
1210mm
35 1/2"
900mm
O
10"
250mm ID
27 3/4"
700mm
AIR INTAKE
9 3/4"
250mm
24 1/2"
620mm
6"
150mm
10 1/2"
270mm
7 3/4"
200mm
3 1/2"
90mm
4 1/4"
110mm
7 1/2"
190mm
20 1/4"
510mm
8"
200mm
27 3/4"
700mm
O
47 1/4"
1200mm
37 1/4"
940mm
160mm
160mm
70"
1780mm
7 1/2"
190mm
29 3/4"
760mm
3 1/2"
90mm
6"
150mm
O
40 1/4"
1020mm
1 1/2"
40mm
9 1/2"
240mm
6 1/4"
160mm
6 1/4"
160mm
O
Front view
Actual weight
1,650 lbs.
Shipping weight
1,850 lbs.
Air intake: Do not
facade or cover over
Must be left
removable for service
Knockouts provided
on Rear Panel for gas/
electrical connection
Rear Panel MUST
be installed
47 1/4"
1213mm
Dual Burner Phoenix Installation
and Operation Manual
PG
8
OF
32
M0030.10 JANUARY 2020
An ongoing program of product improvement may
require us to change specifications without notice.
WOOD STONE CORPORATION
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
TEL
+1.360.650.1111
FAX
+1.360.650.1166
woodstone-corp.com
PX-4836-LR SPECIFICATIONS