13.
Make gas connection at the rear of the Control Box. Gas and electrical connections must comply with all relevant national
and local codes, and in a manner acceptable to the authority having jurisdiction.
Knockouts are provided on the rear of the oven stand for the incoming gas and electrical supplies. If necessary, holes may
be drilled in a side panel for the incoming gas and electrical. Gas and electrical supplies should be routed in such a way
that they do not interfere with the removal of the oven burner, or block the access to the space under the oven for service.
The area beneath the burner needs to be kept clear of conduit and piping to allow for removal of the burner for service. A
19mm (3/4") full-flow gas shut-off valve should be installed on the gas supply near the oven in such a way that it is readily
accessible.
THE REAR PANEL OF THE OVEN MUST BE INSTALLED FOR PROPER FUNCTIONING.
ELECTRICAL CONNECTION
This appliance must be electrically grounded in accordance with local code, or in the absence of local code, with
the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable.
An Electrical Diagram is provided inside the bottom cover of the Control Box, and at the end of this manual.
Connect the incoming
gas supply to the
3/4-inch FNPT gas inlet.
For non-plug models, make the electrical
connection to the terminals in Junction Box.
Correct voltage is specified on the Junction Box
and the Equipment Data Plate.
Dual Burner Phoenix Installation
and Operation Manual
PG
21
OF
32
M0030.10 JANUARY 2020
An ongoing program of product improvement may
require us to change specifications without notice.
WOOD STONE CORPORATION
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
TEL
+1.360.650.1111
FAX
+1.360.650.1166
woodstone-corp.com
UTILITY CONNECTIONS
ASSEMBLY-CONNECTIONS