UTILITY INFORMATION
The Robata Grill 1900 is equipped with one 1/2" NPT gas inlet connection in the rear of the unit� Have a licensed gas installer
provide the hook-up and test all fittings and pipe connections for leaks� Use approved gas leak detectors (soap solutions or
equivalent) over and around the fittings and pipe connections�
DO NOT USE A FLAME TO TEST FOR LEAKS!
Wood Stone recommends that a manual, individual appliance shutoff valve be supplied, located between the grill and the main gas
supply, and be left readily accessible�
MANIFOLD PRESSURE / GAS RATING
This appliance is equipped with a gas pressure regulator suitable for incoming pressure of up to 1/2 psi (14" W�C�)�
If incoming pressure exceeds 1/2 psi (14" W�C�), a suitable regulator, by others, must be installed�
Manifold pressure can be checked at the tap provided, which is located just beyond the outlet side of the regulator�
MANIFOLD PRESSURE / GAS RATING
WS-LGROBG-900
Natural Gas (NG):
4�0" W�C�
47,000 BTU/hr
Propane (LP):
10�0" W�C�
47,000 BTU/hr
Rear view
Regulator
UTILITY CONNECTIONS
Gas connections to the grill are made at the back of the unit.
The installation of this appliance must conform with local codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas Installation Code, CAN/CGA-B149.1 as applicable including:
The appliance and its individual shutoff valve (supplied by others) must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve (supplied
by others) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi
(3.5 kPa).
1/2" NPT gas inlet connection