GAS SPECIFICATIONS
FACTORY SPECIFIED VALVE OUTLET PRESSURES
Models
Note:
“L” or “R” in model number reflects the location of the
radiant flame burners� Coal will burn on the opposite side�
Underfloor Infr
ar
ed
(IR) Bur
ner
Left Side
Flame Bur
ner
Right Side
Flame Bur
ner
Natur
al Gas (NG)
Liquid Propane (LP)
Maximum
Gas
BTU/hr Input
Valve Outlet
Pressure
(W.C.)
SV
-1
SV
-2
WS-FD-(9660 and 11260)-RFG-L-IR-CL (Coal)
1
1
NG
225,000
3�5"
5"
LP
225,000
9"
10"
WS-FD-(9660 and 11260)-RFG-R-IR-CL (Coal)
1
1
NG
225,000
3�5"
5"
LP
225,000
9"
10"
GAS CONNECTION
The Fire Deck 9660 and Fire Deck 11260 are equipped with a 1-inch FNPT gas connection� Have a licensed gas installer provide
the hook-up and test all fittings and pipe connections for leaks� Use approved gas leak detectors (soap solutions or equivalent)
over and around the fittings and pipe connections�
DO NOT USE A FLAME to test for leaks.
All gas piping up to the oven must have a minimum inside diameter of 1", including all fittings and shut off valves, which should
be of the full flow type�
Wood Stone recommends that the Fire Deck be equipped with a manual, individual shutoff valve, located between the oven and
the main gas supply, and that this shutoff valve (supplied by others) be left readily accessible� Wood Stone also recommends that
inspection and maintenance of the burners and gas piping connections of this appliance be performed at regularly scheduled
intervals and only by professional gas appliance service agencies�
This oven requires no modifications or adjustments for use at high altitudes.
The installation of this appliance must conform with local codes, or in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1 or The Natural Gas Installation Code CAN/CGA-B149.1 as applicable.
SV-1 is the gas control valve that operates the Underfloor Infrared (IR) Burner� The manifold pressure is checked at the outlet port
on the SV-1 gas valve�
SV-2 (and SV-3 / SV-4 if equipped) are the gas control valve(s) that operate the interior Radiant Burner(s)� The manifold pressure
is checked at the outlet port on the the individual gas valve�
The burner manifold pressures have been adjusted and tested at the factory� A variety of factors can influence these pressures,
so be sure to test the individual burner manifold pressures and adjust the valves as necessary to achieve the required pressures�
NOTE:
The gas valves are shipped in the
ON
position�