![Wood-mizer SLAB-MIZER MB200AF Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/wood-mizer/slab-mizer-mb200af/slab-mizer-mb200af_installation-manual_994586014.webp)
SLAB-MIZER AUTO FEED INSTALLATION
Publication 2/17/21
14 of 18
Form 2452
5.
Use a straight edge to align the switch within 1/32” to 1/16”
parallel to the edge of the frame
. See FIG. 19.
NOTE
: With power on, the switch will light
when the limit stop bracket is close enough
for operation.
6.
Set the switch in place by tightening both mounting nuts.
7.
Route the feed switch cable.
a.
Unbolt the two bracket bolts identified in FIG. 20.
b.
Place the cable in an EMT cable clamps.
c.
Reattach the bolts in the brackets with the cable
clamps.
d.
Use the four 6mm bolts, washer, and nuts to attach the cable along the front gantry
frame with four cable clamps. See FIG. 20.
e.
Install both cable grips in the holes on the side of the control box.
f.
Thread the feed switch cable through the hole closer to the gantry frame.
FIG. 20
1/32 -1/16”
FIG. 19