Maintenance
Blade Tensioner
Maintenance
30Sdoc120507
3-9
3
3.
Add an Automatic Transmission Fluid (ATF) such as Dexron III ATF to the hydraulic blade
tensioner as needed.
See Figure 3-5.
To add enough fluid to completely fill the tensioner block:
Remove the tensioner handle and ball. Remove the sawmill blade housing covers,
blade and idle-side blade wheel.
Push the idle-side shaft housing all the way in to collapse the rear tensioner piston
and fully extend the front piston. The front piston should reach the threaded area of
the piston guide.
NOTE:
If the hydraulic fluid level is extremely low, collapsing the rear piston may not
fully extend the front piston. If it does not, finish the fill procedure in its entirety and
repeat. The first pass should add enough fluid to allow the front piston to fully
extend. The second pass should add enough fluid to completely fill the block.
Locate the fill plug behind the tension gauge. Clean any dirt and debris from the
plug area. Use a 7/16” wrench to remove the plug, making sure to keep the plug
o-ring with the plug.
Manually extend the rear piston (the front piston should remain extended).
Use a small funnel or cup to completely fill the block with hydraulic fluid. When full,
place the fill plug in the fill plug hole and thread 1-2 turns. Manually push the rear
piston all the way in to allow excess oil and air to bleed from system through the
plug. Tighten the plug all the way.
Reinstall the idle-side blade wheel, blade and blade housing covers. Reinstall the
tensioner ball and handle.
FIG. 3-5
Tension Handle and Ball
Front Piston
Piston Guide
Rear Piston
3H0610
Fill Plug
Gauge