Commercial Series Cyclone Owners Manual

April 2012

Safety

• All installation and operations must follow STATE and LOCAL CODES These CODES 

  may differ from this manual. Installation must be performed by a qualified 

 installer.

• Never open the ash door during operation!

• Anyone who is not familiar with and/or has not been trained to operate the 

  Ash Extraction System may not operate the system. Only responsible adults 

  should operate the Cyclone Separator. If the Cyclone Separator is not operated 

  properly, damage could result and the warranty may be voided.

• Never allow children to play near or tamper with the Cyclone Separator,or any 

  part of the system. 

• Always keep the area around and in front of the system clean and free from 

  combustible materials.

• Keep animals away from the system.

• The operation may not be continued or restarted in the event of visible damages 

  (for example, thermal distortion, traces of smoke or fire, mechanical 

  damages, etc.). Any damages must be repaired. In the event of any doubts, 

  please contact your authorized WoodMaster Dealer.

• Only touch the handles during the operation. Temperatures at other points (for 

  example, chimney, ash door…) can be very high.

• The Cyclone must be operated exclusively according to the guidelines for 

  planning, assembly, regulations, statutes and product related instructions. The 

  manufacturer is not liable for damages and their results, if they occurred due to 

  improper assembly, operation, application and also inadequate maintenance and 

  cleaning.

• Read and follow these directions carefully. Retain this manual for as long as you 

  own your Cyclone Separator.

Содержание COMMERCIAL Series

Страница 1: ...Northwest Manufacturing Inc 600 Polk Ave SW Red Lake Falls MN 56750 www woodmaster com 800 932 3629 Manual PN 7994 405 Retain this manual Cyclone Separator WOODMASTER COMMERCIAL SERIES Rev 2 1 ...

Страница 2: ...s 7 9 Transport Installation 10 Operation 11 Cleaning 12 Maintenance 13 Notes 14 Warranty 15 18 Notes 19 IMPORTANT THIS MANUAL CONTAINS ALL THE NECESSARY INFORMA TION FOR THE CORRECT AND SAFE OPERATION OF THE CY CLONE SEPARATOR IT MUST BE CAREFULLY READ BEFORE INSTALLATION AND ALL MAINTENANCE AND REPAIR OPERATIONS ...

Страница 3: ...idered a courtesy only Our customer service is always available for providing information on updates of WoodMaster Cyclone Separators upon request Aim of the document This Instruction Manual has been written to provide the user and the installer with a general knowledge of the Cyclone Separator and the assembly use and maintenance instructions that are necessary for operating the Cyclone Separator...

Страница 4: ... in case of damages to people or objects due to a improper Cyclone Separator use b use of the Cyclone Separator by untrained personnel c serious lack of maintenance d unauthorised modifications and interventions e use of non original spare parts or not compatible with that model f total or partial failure to comply with the instructions g extraordinary events h use of the Cyclone Separator for pur...

Страница 5: ...the system clean and free from combustible materials Keep animals away from the system The operation may not be continued or restarted in the event of visible damages for example thermal distortion traces of smoke or fire mechanical damages etc Any damages must be repaired In the event of any doubts please contact your authorized WoodMaster Dealer Only touch the handles during the operation Temper...

Страница 6: ...vention threshold no higher than 30 mA NOISE HAZARD Risk of NOISE due to uncleanly conditions of the fan vanes FINGER INJURY HAZARD During control and maintenance operations on chain transmission components located in correspon dence of the gear motor SUSPENDED LOAD HAZARD During transport and handling operations ASPHYXIATION HAZARD Risk of ASPHYXIA in the event of insufficient suction of fumes We...

Страница 7: ...f the walls travel at the same speed the angular speed of the particles is inversely proportional to the wall s radius The cen trifugal force increases with the angular speed square therefore the friction on the walls of a cyclone with a smaller diameter also increase The Cyclone Separator consists of a fume input cham ber in which small cylinders composed of cylindrical hoppers equipped with a sy...

Страница 8: ... and a more or less el evated humidity content Biomass products may include those with low moisture content such as dry wood sawdust wood chips pel lets nutshells nuts etc or products that have an average humidity content including pruning branches corn etc of products with high humidity content such as grass leaves and grape seeds etc During combustion each of these products produces fumes that c...

Страница 9: ...ng fea tures Model A mm B mm C mm D mm E mm F mm G mm H x K Cyclone N Weight daN kW MTC500 1510 1260 500 140 250 150 1150 100x140 2 300 0 18 MTC1000 1600 1200 580 185 350 200 1100 112x160 4 400 1 1 MTC2000 2200 1900 780 205 500 250 1600 125x180 9 600 2 2 MTC4000 2600 2300 1000 255 750 300 2000 200x280 16 850 3 MTC8000 3300 3000 1400 405 1000 400 2500 280x400 36 1150 5 5 ...

Страница 10: ...two pieces Transport and Handling Handling operations must be carried out with adequate vehicles that have a capacity equal to or exceeding the weight indicated on the identification plate Installation and testing Testing may be carried out only once the Cyclone Separator has been installed completely that is positioned and levelled out and connected to the electrical panel heat generator and chim...

Страница 11: ...ration as explained on page 7 depends on many factors that are difficult to influence hu midity and weight of the combustible outside air temperature or that can be influenced by adjusting the heat generator temperature of fumes flow of fumes The efficiency of dust removal is connected to the fume flow and consequently its speed of passage through the Cyclone Separator A speed that is too low resu...

Страница 12: ...aving passed through the cyclones are collected in an upper plenum on which the fan connection fitting is located The reduction in speed consequent of the passage from the return tubes of a restricted diameter to the plenum chamber may cause the depositing of residual ash on the plenum plate To clean the plate remove the fitting with the valve that connects the filter to the fan Cleaning the fan T...

Страница 13: ...rotary valve to run until no ash is present SHUT OFF the power to the rotary valve and allow to cool before manually cleaning To clean open the door on the cyclone and use a wire brush or similar to clean the valve Apply a rust inhibitor to the rotary valve to prevent corrosion during the off season Cyclone Separator The Cyclone should be emptied and cleaned of ash at the end of the season shutdow...

Страница 14: ...14 Commercial Series Cyclone Owners Manual April 2012 Notes ...

Страница 15: ...turing Inc shall be deemed to be the Date of Original Installation WARRANTY LIMITATIONS I Damages for unsatisfactory performance caused by improper installation or any damages caused by or as a result of improper use of the System incorrect start up incorrect or careless handling improper control adjustment disregard of the operating instructions and proper maintenance or disregard of any other in...

Страница 16: ...ducts that are a not sold in Canada or the United States b not installed in Canada or the United States or c not purchased from an Authorized Distributor VII Northwest Manufacturing Inc shall not be responsible for any consequential damages direct or indirect caused by the products described in this Warranty VIII The Warranty for this System is also subject to the terms of the Warranty for the Woo...

Страница 17: ...Northwest Manufacturing Inc 600 Polk Ave SW Red Lake Falls MN 56750 Northwest Manufacturing Inc 600 Polk Ave SW Red Lake Falls MN 56750 PLACE POSTAGE HERE ...

Страница 18: ...Serial Number Model Name How did you learn about our product Radio Newspaper Internet TV Print Other Would you like information on other products from Northwest Manufacturing Inc Yes No Thank you for purchasing a WoodMaster Commercial Series Boiler I have read the owners manual and understand the proper usage of my Boiler Customer s Signature Printed Name Contractor s Signature Printed Name Fold F...

Страница 19: ...19 Commercial Series Cyclone Owners Manual April 2012 Notes ...

Страница 20: ...Commercial Series Cyclone Owners Manual Northwest Manufacturing Inc 600 Polk Ave SW Red Lake Falls MN 56750 www woodmaster com 800 932 3629 Manual PN 7994 400 ...

Отзывы: