CLEANFIRE OUTDOOR FURNACE • OWNER'S MANUAL
CIRCUIT BREAKER
The circuit breaker is located in the pump access area and also serves
as the furnace disconnect. If the circuit breaker trips (turns off), reset it
by turning it on. If the circuit breaker continues to trip, a component may
be faulty. It is possible to isolate a faulty component using the following
procedure.
1. Disconnect power to the outdoor furnace.
Do not proceed without testing that power is disconnected. Make sure the power
cannot be reconnected while testing components (i.e., use lock out, tag out).
2. Remove the airbox access cover; then open the airbox door.
3. Disconnect the actuator motor harness and disconnect the fan
harness.
4. To test for a faulty component, connect one component at a time
(e.g., start with one of the actuator motors); then connect power to
the outdoor furnace. If the circuit breaker trips, the component is likely
faulty. If not, disconnect power to the outdoor furnace and repeat the
procedure until all components have been tested.
CAUTION
Disconnect power to the outdoor furnace before disconnecting a component and
before connecting a component.
5. Close and secure the airbox door. Install the airbox access cover.
Do not connect power or operate the outdoor furnace with the outer airbox cover
removed. The outer airbox cover must be installed and secured with screws.