PTZ SETTING & INSTALLATION
06
MIN PTZ CAMERA
07
MIN PTZ CAMERA
PTZ SETTING & INSTALLATION
1. Loop : RS-485 Termination On/Off
2. Parity : Set the Protocol parity (NONE, EVEN, ODD)
3. Baud : Set the Communication baudrate (2400~19200bps)
4. Protocol : Set the protocol (PELCO-D, PELCO-P, WONWOO)
Unpack carefully. Electronic components can be damaged if improperly handled or dropped. If an item appears to
have been damaged in shipment, replace it properly in its carton and notify the shipper.
Save the shipping carton and packaging material. They are the safest material in which to make future shipments
of the equipment. Keep this Installation and Operating Manual.
Camera must be installed by qualified service personnel in accordance with all local and
federal electrical and building codes. The system should be installed according to as
described
PS-100
Installation bracket
(Surface Mount)
Manual
Alarm cable
1-loose proof screw
(Surface Mount)
3- Installation bracket
Fixing screws
1-loose proof screw
(In-ceiling Mount)
To install and use the PS-100, the followings should be needed. (NOT included in box)
1) Power adaptor (Over 1A)
The power adaptor should have capacity over 1 Ampere.
Low power capacity may cause poor image quality or failure.
2) BNC cable for video signal.
BNC connectors and coaxial cables are closely related with the quality of camera image.
3) RS-485 communication cable (Twist pair)
According to the RS-485 standards, the maximum cable length is 1.2Km
1.PTZ setup (DIP switch)
Before installation, camera have to set ADDRESS, BAUDRATE and PROTOCOL. As below picture, there are setting
DIP switch on the camera bottom.
ⓐ
PTZ communication set
ⓑ
Camera address set
ⓒ
Extra video out
ⓓ
Alarm In and Relay out
ⓔ Power Input, Balun video
out, and RS-485 Communication
ⓐ
PTZ Setting
Unpacking
Preparation for installation
Installation bracket
(In-ceiling Mount)
Extra Video out cable
PH (TTB) 3X10
(M3*6 PH)
(#8*38)
ⓐ
ⓑ
ⓒ
ⓓ
ⓔ
PARITY
RARITY
NONE
EVEN
ODD
NONE
H
OFF
OFF
ON
OFF
L
OFF
ON
OFF
OFF
BAUDRATE
2400bps
4800bps
9600bps
19200bps
H
OFF
OFF
ON
ON
L
OFF
ON
OFF
ON
PROTOCOL
PELCO-D(WPD)
PELCO-P(WPP)
WONWOO(WTX)
H
OFF
OFF
OFF
M
OFF
ON
OFF
L
ON
OFF
OFF