DIMENSIONS & GAS CONSUMPTION
Gas Consumption
This appliance has a maximum gas at input its highest setting of
3.65kW (Gross)
The maximum heat output is 2.7kW.
OPERATING YOUR FIRE
The pilot may be left alight. It is advisable, however, that the pilot is turned
off if the premises are to be left unoccupied for a lengthy period.
For your safety the fire is fitted with a flame supervision device which will
shut off the gas supply if for any reason the pilot goes out. This device
incorporates a fixed probe which senses the heat from the pilot flame. If the
probe is cool the device will prevent any gas flow unless the pilot lighting
knob is held in. This device also stops the fire being turned back on until it is
safe after it has been turned off.
If, for any reason, the fire goes out or if the fire is turned off, always
wait at
least three minutes before attempting to relight
If the device starts to shut off the gas frequently, get expert advice.
To Light the Pilot
•
Push in the right control knob (the pilot lighting knob) and, while keeping it depressed, turn
anticlockwise through the ignition position marked and up to the pilot position marked .
The spark should light the pilot. The pilot flame can be seen by looking through the gap near
the left side of the coal front (See figure 3).
•
When the pilot has lit, keep the right hand control knob depressed for a few seconds to prevent
the flame supervision device from shutting off the gas supply while its probe warms up, as
explained above, then release it. If the pilot does not remain alight turn the knob back to the off
position marked
•
.
Wait a few seconds and repeat the lighting sequence.
To Light the Main Burner
•
Partially depress the right control knob and turn to the main burner position marked .
•
The main burner flames are controlled by using the rocker switch at the right side of the fire case. Operating the rocker switch
automatically causes the knob at the left side of the pilot control knob to rotate. Pressing in the top half of the switch turns the main burner
on. Keeping the top half pressed gradually increases the flame height and heat output. Pressing the bottom half reduces the flame height and
heat output and finally turns the main burner off. In the unlikely event of failure of the rocker switch, the left side knob can be turned
manually.
To Turn Off the Main Burner Only
Press in and hold the bottom half of the rocker switch until the main burner is extinguished. Alternatively, the main burner can be
extinguished by turning the right hand control knob to the pilot position marked .
To Turn Off the Main Burner and Pilot
Turn the right hand control knob to the pilot position marked . Push the knob in at this position and turn to the off position marked
•
.
Figure 3 Pilot flame
Figure 1 Appliance Dimensions
Figure 2 Controls