INSTALLER’S GUIDE
Page
9
increased by 2mm all round.
3.14
Combustible side projections up to 75mm forward of the fixing plane of the
fire are to be a minimum of 125mm from the fireplace opening (See figure 3)
3.14.1
Combustible side projections greater than 75mm forward of the fixing plane
of the fire are to be a minimum of 250mm from the fireplace opening (See figure
3).
3.14.2
Non-combustible side projections to be 75mm from the fireplace opening
(See figure 3)
4. UNPACKING
Contents: -
1
Convector box assembly
1
Accessory kit including: -
4
Lengths of Self Adhesive Foam seal
2
Eyebolts
2
Fibre wall plugs
2
Retaining cables
2
Cable clamps
1
Restrictor plate
1
Stainless steel screw
Check that all the listed parts are present and in good condition.
5. INSTALLATION
OF
APPLIANCE
5.1 Fireplace size
The fireplace must comply with the requirements described in section 3.
5.2 Fireplace flue pull.
Visually inspect the flue for any obstruction, and that a smooth transition from the
fireplace opening into the flue is available. Close all doors and windows in the room in
which the appliance is to be installed. After confirming with a match that smoke is
drawn into the flue, light a 13 gram smoke pellet and check that there is a definite flow
through the flue. Verify outside that the smoke exits from one terminal only and that
the termination is suitable. Observe, where possible, upstairs rooms and loft spaces for
signs of escaping smoke indicating a defective flue. If there is not a definite flow warm
the flue for a few minutes and repeat the smoke pellet test. If there is still no definite