The software (firmware) of your Visualizer (including the o
) can easily be
upgraded to the latest version. The firmware update can be done via USB, Ethernet (LAN)
or RS232.
Firmware update files can be downloaded for free at
www.wolfvision.com/support
.
Updates via USB can be made with the WolfVision USB Software, updates via
Ethernet/LAN require the WolfVision Ethernet Software and updates via RS232 can be
made with WolfVision's Firmware Update Utility. All three programs can also be found on
our homepage.
For RS232 connection, use a crossed serial RS232 cable (Nullmodem-cable).
n-screen HELP
Firmware Upgrades
Dimensions
92
90
7
2
1
2
5
,5
2
0
6
Closed:
Open:
Ceiling mount
Cooling
Air Inlet
Cooling
Air Outlet
All measurements in millimeters (for inch see list)
5
7
,1
135
1
6
0
8
0
160
8
0
4
0
70
6
0
1
2
18
95
3
5
2
452
400
2
8
5
mm
12
0.47
18
0.71
40
1.57
58,1
2.29
60
2.36
70
2.76
72
2.83
80
3.15
90
3.54
92
3.62
95
3.74
125,5
4.94
135
5.31
144
5.67
160
6.3
206
8.11
240
9.45
285
11.22
352
13.86
390
15.35
400
15.75
452
17.8
528
20.79
IMPORTANT NOTE:
DO NOT BLOCK
COOLING AIR
INLET AND
OUTLET!
Inch
MAINTENANCE
The Ceiling Visualizer is fitted with an automatic lamp changer.
If one lamp fails, there is no need to replace it immediately, as the automatic lamp changer
automatically switches to the second
(spare) lamp. When the unit changes
lamps there is
an on-screen message saying: "Changing lamp".
When switching on the unit the Visualizer checks if both lamps are working. If one lamp fails
there will be an
on screen message for a couple of seconds displaying "Lamp x blown".
This prevents a user from forgetting to change a defective lamp.
Automatic Lamp Changer
If the unit gets too hot (improper ventilation or air extraction) a built in thermostat will switch
off the light of the Visualizer. Verify that proper ventilation and air extraction is available and
allow the unit to cool.
Thermostat