![Wolfson WM8804 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/wolfson/wm8804/wm8804_manual_993773005.webp)
Production Data
WM8804
w
PD Rev 4.1 September 2007
5
ABSOLUTE MAXIMUM RATINGS
Absolute Maximum Ratings are stress ratings only. Permanent damage to the device may be caused by continuously operating at
or beyond these limits. Device functional operating limits and guaranteed performance specifications are given under Electrical
Characteristics at the test conditions specified.
ESD Sensitive Device. This device is manufactured on a CMOS process. It is therefore generically susceptible
to damage from excessive static voltages. Proper ESD precautions must be taken during handling and storage
of this device.
Wolfson tests its package types according to IPC/JEDEC J-STD-020B for Moisture Sensitivity to determine acceptable storage
conditions prior to surface mount assembly. These levels are:
MSL1 = unlimited floor life at <30
°
C / 85% Relative Humidity. Not normally stored in moisture barrier bag.
MSL2 = out of bag storage for 1 year at <30
°
C / 60% Relative Humidity. Supplied in moisture barrier bag.
MSL3 = out of bag storage for 168 hours at <30
°
C / 60% Relative Humidity. Supplied in moisture barrier bag.
The Moisture Sensitivity Level for each package type is specified in Ordering Information.
CONDITION
MIN MAX
Digital core and I/O buffer supply voltage
-0.3V +5V
PLL supply voltage
-0.3V +5V
Voltage range digital inputs
DGND -0.3V
DVDD +0.3V
Master Clock Frequency
37MHz
Operating temperature range, T
A
-25
°
C +85
°
C
Storage temperature
-65
°
C +150
°
C
Note
:
1.
PLL and digital supplies must always be within 0.3V of each other.
2.
PLL and digital grounds must always be within 0.3V of each other.