IMPORTANT NOTE: Additional clearance
between warming drawer and oven openings
may be required. Check that oven supports do
not obstruct the interior dimensions required
for the warming drawer.

When the warming drawer is installed below
a built-in oven, a minimum of 1

1

/

2

" (38)

between warming drawer and oven openings
is required for placement of the anti-tip block
and oven platform. When installed above a
built-in oven, a minimum of 

7

/

8

" (22) is

required.

IMPORTANT NOTE: In an overlay application,
the amount of space between warming drawer
and built-in oven openings may need to be
increased depending on the size of the overlay
panel and the amount of overlap.

I N T E G R AT E D  

D R A W E R F R O N T

I N S T A L L A T I O N  W I T H   B U I L T- I N   O V E N

The Wolf warming drawer with integrated
drawer front may be installed below or above
a Wolf 30" (762) or 36" (914) built-in single
oven, provided the warming drawer is fully
enclosed, top and bottom. Refer to the
illustration below. Also refer to installation
instructions provided with the built-in oven for
additional specifications. Dimensions will vary
according to the specific installation.

The Wolf warming drawer is designed and
agency approved for installation with Wolf
built-in ovens.

The warming drawer platform must be able to
support 200 lbs (91 kg). It must be a minimum
of 1" (25) above the toe kick to allow for the
overlap of the warming drawer trim.

NOTE: Refer to the built-in 30" (762) single oven specifications for electrical location.

INSET APPLICATION

OVERLAY APPLICATION

27

3

/

16

"

(691)

24"

min

(610)

24"

min (610)

OPENING DEPTH

24"

min (610)

CABINET DEPTH

27

3

/

16

"

(691)

24"

min

(610)

24"

(610) + THICKNESS

OF DRAWER FACE

FOR OPENING DEPTH

25"

min (635)

CABINET DEPTH

29

1

/

2

"

(749)

WARMING DRAWER

OPENING WIDTH 

28

1

/

2

"

(724)

30-INCH OVEN

OPENING WIDTH 

33" 

(838)

CABINET WIDTH

E

5"

(127)

4"

(102)

1

1

/

2

"

min

*

(38)

1

1

/

2

"

min

*

(38)

10

1

/

4

"

(260)

OPENING

HEIGHT

9

7

/

8

"

(251)

2"

(51) x 

2"

(51)

ANTI-TIP BLOCK

10

1

/

4

"

(260)

OPENING

HEIGHT

9

7

/

8

"

(251)

2"

(51) x 

2"

(51)

ANTI-TIP BLOCK

*Dimension may increase depending on the size of the drawer front panel.

Installation with Built-In Oven – Integrated Drawer Front

Содержание WWD30

Страница 1: ...INSTALLATION INSTRUCTIONS W A R M I N G D R A W E R ...

Страница 2: ...would like to identify is IMPORTANT NOTE This highlights informa tion that is especially relevant to a problem free installation signals a situation where minor injury or product damage may occur if you do not follow instructions states a hazard that may cause serious injury or death if precautions are not followed WOLF is a registered trademark of Wolf Appliance Company LLC C O N TA C T I N F O R...

Страница 3: ...structions prior to installation Save these instructions for the local inspector s refer ence then leave them with the homeowner Homeowner Please read and keep these instructions for future reference and be sure to read the entire Use Care Information prior to use Any questions or problems about the installation should be directed to your Wolf dealer or Wolf Appliance Company LLC at 800 332 9513 Y...

Страница 4: ...integrated drawer front application A C C E S S O R I E S Optional acces sories are available through your Wolf dealer To obtain local dealer information visit the Locator section of our website wolfappliance com BEFORE YO U S TA RT Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Wolf warranty Refer to the Warming Dra...

Страница 5: ... E R C O U N T E R I N S TA L L AT I O N For undercounter installations 231 2 597 from the bottom of the warming drawer opening to the floor is recommended It must be installed a minimum of 5 127 above the floor or 1 25 above the toe kick The Wolf warming drawer with stainless steel drawer front may be installed below an electric or gas cooktop provided the warming drawer is fully enclosed top and...

Страница 6: ... oven for additional specifications Dimensions will vary according to the specific installation The Wolf warming drawer is designed and agency approved for installation with Wolf built in ovens The warming drawer platform must be able to support 200 lbs 91 kg It must be a minimum of 1 25 above the toe kick to allow for the overlap of the warming drawer trim Installation with Built In Oven Stainles...

Страница 7: ...nation with a 30 762 single oven and microwave oven with 30 762 trim provided the warming drawer is fully enclosed top and bottom Refer to the illustration below Also refer to installation instructions provided with the built in oven and microwave for additional specifications Dimensions will vary according to the specific installation The warming drawer platform must be able to support 200 lbs 91...

Страница 8: ...lacement of anti tip block and drawer face overlap Overlap of decorative drawer face will vary depending on the size of the custom panel 101 4 260 OPENING HEIGHT 97 8 251 2 51 x 2 51 ANTI TIP BLOCK 293 8 746 OVERALL WIDTH 231 2 597 BEHIND FRAME 9 229 101 8 257 Overall Dimensions Integrated Drawer Front Integrated Drawer Front Overlay Application INTEGRATED D R AW E R F RO N T I N S TA L L AT I O N...

Страница 9: ...ORTANT NOTE The inset application requires the warming drawer to be recessed into the cabinet A minimum 25 635 deep cabinet is needed if you want the front panel to be flush with surrounding cabinetry If you are installing the warming drawer with integrated drawer front in an inset application a minimum 33 838 wide and 25 635 deep cabinet is required for this installation A minimum base support of...

Страница 10: ...d bottom Refer to the illustration below Also refer to installation instructions provided with the built in oven for additional specifications Dimensions will vary according to the specific installation The Wolf warming drawer is designed and agency approved for installation with Wolf built in ovens The warming drawer platform must be able to support 200 lbs 91 kg It must be a minimum of 1 25 abov...

Страница 11: ...ven and Microwave Integrated Drawer Front Refer to installation instructions provided with the built in oven and microwave for additional specifications Dimensions will vary according to the specific installation The Wolf warming drawer with integrated drawer front may be installed next to or above another Wolf warming drawer provided each unit is fully enclosed top and bottom INTEGRATED D R AW E ...

Страница 12: ... it is placed behind the unit make sure the outlet is flush with the back wall For location of the electrical outlet refer to the installation illustration for your specific installation on pages 5 11 The electrical outlet can be located in an adjacent cabinet within reach of the power cord If the outlet is located in an adjacent cabinet you will need to drill a 2 51 diameter hole in the cabinet w...

Страница 13: ...sh with the bottom edge of the opening They must be able to support 200 lbs 91 kg If an integrated drawer front is used it must be supported by a 5 8 16 solid platform The platform will need to be recessed and allow for overlap of the warming drawer collar Refer to page 16 for additional details The platform must be level rigidly mounted and must be able to support 200 lbs 91 kg IMPORTANT NOTE Mak...

Страница 14: ... 16 8 long screws provided in the kit to secure these two pieces together Repeat this process to attach the right side and bottom trim 14 W O L F WARMING DRAWER STAINLESS STEEL F RO N T PA N E L I N S TA L L A N T I T I P B L O C K I N G Install a 2 51 x 2 51 or 2 51 x 4 102 anti tip block against the rear cabinet wall When the warming drawer is installed below a built in oven you may use a 7 8 22...

Страница 15: ...er front assembly and tighten screws Refer to the illustration below Turn power off to the electrical outlet I N S TA L L WA R M I N G D R AW E R Slide the left corner of the warming drawer into the opening If the electrical outlet is installed inside the opening plug the power cord into the outlet The excess cord should be coiled behind or beside the unit If the outlet is located in an adjacent c...

Страница 16: ...at it can support a minimum of 200 lbs 91 kg Refer to the illustrations below IMPORTANT NOTE In an overlay application be sure to recess the cleats no more than 3 16 5 Recessing deeper than this may cause the drawer to not close properly W O L F WARMING DRAWER IMPORTANT NOTE Be sure to finish the inside lip of the opening and the front face of the shelf and cleats Some of these areas will be visib...

Страница 17: ...o the opening If the electrical outlet is installed inside the opening plug the power cord into the outlet The excess cord should be coiled behind or beside the unit If the outlet is located in an adjacent cabinet thread the power cord through the hole in the cabinet wall Push the unit back into the opening until the warming drawer collar meets up with the recessed cleats and platform Make sure th...

Страница 18: ...e edge of the oblong holes to the the corresponding oblong hole below it The markings on the back of the decorative panel should look like the bottom panel illus tration below For every round marking on the decorative panel 12 locations drill a 1 2 hole 1 4 6 deep in the back of the panel Route out the rectangular areas 8 locations marked on the back of the decorative panel 1 4 6 deep Attach the h...

Страница 19: ...alling a Wolf authorized service center For the name and number of the Wolf authorized service center nearest you check the Locator section of our website wolfappliance com or call Wolf Customer Service at 800 332 9513 When calling for service you will need the model and serial numbers of the warming drawer Both numbers are listed on the product rating plate located on the left front floor area of...

Страница 20: ...8 0 8 2 1 2 4 2 0 0 6 WOLF APPLIANCE COMPANY LLC P O BOX 44848 MADISON WI 53744 800 332 9513 WOLFAPPLIANCE COM ...

Отзывы: