Gas Cooktop Installation

10

GAS SUPPLY LINE

IMPORTANT NOTE:

The gas cooktop must be connected

to a regulated gas supply.

A gas supply line of

3

/

4

"

(19)

rigid pipe must be provided to

the cooktop. For LP gas, piping or tubing size can be

1

/

2

"

(13)

minimum. LP gas suppliers usually determine the size

and materials used on the system. If local codes permit, a

certified,

1

/

2

"

(13)

or

3

/

4

"

(19)

ID flexible metal appliance

connector is recommended to connect the cooktop to the

gas supply line. The gas pressure regulator on the

cooktop has

1

/

2

"

(13)

female threads.

IMPORTANT NOTE:

The supply line must be equipped

with an approved external gas shut-off valve located near

the cooktop in an accessible location. Do not block

access to the shut-off valve. Refer to the illustration below.

Wolf natural gas cooktops will function up to an altitude of

10,250'

(3124 m)

without any adjustment. LP gas cooktops

will function up to 8,600'

(2621 m)

without adjustment. If

the installation exceeds these elevations, contact your

authorized Wolf dealer for a high altitude conversion kit.

Gas Supply Requirements

IMPORTANT NOTE:

This installation must conform with

local codes and ordinances. In the absence of local

codes, installations must conform with the American

National Standard, National Fuel Gas Code.

TYPES OF GAS

There are two types of gas, natural and liquid propane

(LP). Conversions are required in order for appliances

designed for one gas to be operated with the other gas.

Such conversions must be performed by Wolf factory

certified service. Make sure your gas cooktop is correctly

adjusted for the type of gas being used.

The product rating plate has information on the type of

gas that should be used. If this information does not agree

with the type of gas available, check with the local gas

supplier. The rating plate is located on the underside of

the cooktop. Refer to the illustration on page 3.

SHUT-OFF VALVE

OPEN POSITION

GAS SUPPLY

TO APPLIANCE

Shut-off valve.

EXPLOSION HAZARD: Use a certified gas supply line

and install a gas shut-off valve. Securely tighten all gas

connections. Failure to follow these instructions can

result in explosion, fire or death.

Before connecting the gas supply, make sure all valves

are in a closed position. Do not connect the gas supply

to an appliance that shows any sign of damage.

Содержание REV-A 5/2010 814990

Страница 1: ...INSTALLATION GUIDE Gas Cooktops ...

Страница 2: ... instructions are not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed Contents Wolf Gas Cooktops 3 Safety Instructions 4 Gas Cooktop Specifications 5 Gas Cooktop Installation 9 Service Information 15 Features and specifications are subject to change at any time without notice Visit wolfappliance com specs for the most up to date information I...

Страница 3: ...ct voltage frequency and amperage must be supplied to the appliance from a dedi cated grounded circuit which is protected by a properly sized circuit breaker or time delay fuse The proper voltage frequency and amperage ratings are listed on the product rating plate Wolf gas cooktops are manufactured for use with natural gas or LP gas Check the product rating plate for the type of gas for your spec...

Страница 4: ...store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance A ventilation hood is recommended but not required for use with the Wolf gas cooktop In Massachusetts Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the state province or region where this appliance is being inst...

Страница 5: ...cifications 5 wolfappliance com specs 7 8 22 ALL SIDES 4 102 21 533 15 381 30 762 7 8 22 ALL SIDES 4 102 21 533 36 914 7 8 22 ALL SIDES 4 102 21 533 15 381 COOKTOP 30 762 COOKTOP 36 914 COOKTOP Gas Cooktop Dimensions ...

Страница 6: ... 2 64 min 7 178 TO COMBUSTIBLE 7 178 TO COMBUSTIBLE SIDE CABINET 13 330 max E 15 381 15 381 4 102 18 457 min 5 127 LOCATION OF GAS AND ELECTRICAL EXTENDS ON FLOOR G 21 2 64 min FRONT VIEW SIDE VIEW Minimum clearance from cooktop cut out to combustible materials up to 18 457 above countertop NOTE Application shown allows for installation of two 15 381 modules side by side 15 381 Gas Cooktop INSTALL...

Страница 7: ... 9 229 TO COMBUSTIBLE 9 229 TO COMBUSTIBLE SIDE CABINET 13 330 max 29 737 CUT OUT WIDTH COUNTERTOP CUT OUT FRONT 191 4 489 CUT OUT DEPTH 21 2 64 min G 21 2 64 min SIDE VIEW FRONT VIEW Minimum clearance from cooktop cut out to combustible materials up to 18 457 above countertop NOTE Gas and electrical location applies only to installation with built in oven 30 762 Gas Cooktop INSTALLATION ...

Страница 8: ...T OUT WIDTH COUNTERTOP CUT OUT FRONT 191 4 489 CUT OUT DEPTH 21 2 64 min 9 229 TO COMBUSTIBLE 9 229 TO COMBUSTIBLE SIDE CABINET 13 330 max 21 2 64 min FRONT VIEW SIDE VIEW Minimum clearance from cooktop cut out to combustible materials up to 18 457 above countertop NOTE Gas and electrical location applies only to installation with built in oven 36 914 Gas Cooktop INSTALLATION ...

Страница 9: ...Wolf ventilation guide Failure to locate the cooktop without the proper clear ances will result in a fire hazard MULTIPLE COOKTOP INSTALLATION If the gas cooktop is to be used with any combination of additional cooktops or modules with a filler strip the dimensions provided in the chart are derived by adding 11 4 32 additional space for each additional unit to give you the total countertop cut out...

Страница 10: ...kit Gas Supply Requirements IMPORTANT NOTE This installation must conform with local codes and ordinances In the absence of local codes installations must conform with the American National Standard National Fuel Gas Code TYPES OF GAS There are two types of gas natural and liquid propane LP Conversions are required in order for appliances designed for one gas to be operated with the other gas Such...

Страница 11: ... The Wolf gas cooktop requires a 120 V AC 60 Hz electri cal supply to operate the electronic ignition system The service should have its own 15 amp circuit breaker A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation The cooktop is equipped with a power cord with a 3 prong grounding plug To minimize shock hazard the power cord must be plugged into a ma...

Страница 12: ... WHITE WHITE LEFT REAR RIGHT REAR RIGHT FRONT LEFT FRONT BLK WHITE WHITE WHITE BLK BLK BLK BLK 3 CONDUCTOR POWER CORD BLK RED RED RED IGN IGN IGN IGN N A A N A N A N A N 1 1 2 2 CEN REAR CF SPARK MODULE LF SPARK MODULE LR SPARK MODULE CR SPARK MODULE WHITE WHITE GRN RED RED RED RED RED BLACK WHITE WHITE WHITE LEFT REAR RIGHT REAR CEN FRONT LEFT FRONT RR SPARK MODULE BLK WHITE WHITE WHITE WHITE BLK...

Страница 13: ...op frame with the pencil line and check that it is parallel to the front edge of the countertop Lift the entire cooktop to make adjustments Attach the brackets to the bottom of the unit Insert the 31 2 89 clamping screws into the brackets Use a screw driver to tighten the clamping screws against the under side of the countertop Refer to the illustration below Do not overtighten screws IMPORTANT NO...

Страница 14: ... control knob is pushed in and turned to the HIGH position the system creates a spark to light the burner This sparking continues until the electronic ignition senses a flame Before lighting place the burner head and cap on each burner base and position the burner grates To check operation of the surface burners push in and turn each control knob to the HIGH position The flame should light within ...

Страница 15: ...ed service nearest you check the contact support section of our website wolfappliance com or call Wolf customer care at 800 222 7820 When calling for service you will need the model and serial numbers of the gas cooktop Both numbers are listed on the product rating plate located on the under side of the cooktop Refer to the illustration below wolfappliance com specs The information and images in t...

Страница 16: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 222 7820 814990 REV A 3 2011 ...

Отзывы: