background image

3

Dimensions in parentheses are in
millimeters unless otherwise specified.

Planning Information

Pro 27"

(686)

Deep Wall Ventilation Hood

M O D E L   P W 4 2 2 7 1 8 ( R )

S P E C I F I C A T I O N S

Overall Width of Hood

42" (1067)

Overall Height of Hood

18" (457)

Overall Depth of Hood

27" (686)

(including rail)

29" (737)

Internal Blower Options

600 or 900 CFM

In-Line Blower Option

1100 CFM

Remote Blower Options

900, 1200 or 1500 CFM

Discharge

Vertical or Horizontal*

Duct Size

10" (254) Round

Electrical Supply Requirements

110 / 120 V AC, 60 Hz

15 amp dedicated circuit

Shipping Weight (shell only)

118 lbs (54 kg)

*Horizontal discharge applications require a horizontal discharge kit.

Specifications are subject to change without notice.

B L O W E R   O P T I O N S

600 CFM Internal Blower

810559

900 CFM Internal Blower

811131

1100 CFM In-Line Blower

808332

900 CFM Remote Blower

801641

1200 CFM Remote Blower

801642

1500 CFM Remote Blower

804701

Refer to Pro Ventilation Recommendations
at the end of this section.

A C C E S S O R I E S

Platinum or brass decorative rail
and stand-offs

38" (965) high classic stainless
steel backsplash with or without
warming racks

6" (152), 12" (305), 18" (457) and
24" (610) classic stainless steel
duct covers

Horizontal discharge kit

Accessories are available through your
Wolf dealer. To obtain local dealer
information, visit the Showroom Locator
section of our website, wolfappliance.com.

Содержание PW422718

Страница 1: ...ll hoods this 27 686 model provides an additional exclusive feature heat lamps Pro wall ventilation hoods are recommended for use with all Wolf cooking appliances For optimal perform ance a Pro 27 686 deep wall hood is recommended for use with ranges and rangetops that contain a charbroiler or griddle Wolf Pro 27 686 deep wall hoods are available in the classic stainless steel finish Rail option h...

Страница 2: ...and sides and hand finished craftsmanship Recessed easy access controls Infinite speed blower control Heat sentry feature automatically turns unit on when heat is sensed and automatically adjusts blower speed Halogen lighting with two settings Heat lamps bulbs not included Removable dishwasher safe restaurant grade stainless steel baffle filters Transition with backdraft damper included CSA listed...

Страница 3: ...rizontal discharge applications require a horizontal discharge kit Specifications are subject to change without notice B L O W E R O P T I O N S 600 CFM Internal Blower 810559 900 CFM Internal Blower 811131 1100 CFM In Line Blower 808332 900 CFM Remote Blower 801641 1200 CFM Remote Blower 801642 1500 CFM Remote Blower 804701 Refer to Pro Ventilation Recommendations at the end of this section A C C...

Страница 4: ...th of Hood 42 1067 Overall Height of Hood 18 457 Overall Depth of Hood excluding rail 27 686 Countertop to Bottom of Hood 30 762 to 36 914 Location of Electrical Within shaded area See Installation Instructions shipped with unit for detailed specifications I N S T A L L A T I O N S P E C I F I C A T I O N S Dimensions in parentheses are in millimeters unless otherwise specified Planning Informatio...

Страница 5: ...4 Wolf Pro wall hoods are shipped without a blower assembly Internal in line or remote blower assemblies are available Blower options also vary with the volume of air that needs to be moved and the length of the duct run Refer to the charts at the end of this section for Pro ventilation recommendations and blower options IMPORTANT NOTE Install this ventilation hood only with a Wolf blower Pro wall...

Страница 6: ...ICAL DISCHARGE D U C T I N G C O N S I D E R A T I O N S Wolf Pro 27 686 deep wall hoods are shipped without the blower assembly Internal in line and remote blower assemblies are available IMPORTANT NOTE Install this ventilation hood only with a Wolf blower Pro 27 686 deep wall hoods have a vertical discharge A horizontal discharge kit is available as a sales accessory The hood will operate most e...

Страница 7: ...e blowers are mounted in between the hood and the exterior of the home Remote blowers can be mounted on the roof or in some cases on an exterior wall Refer to the illustra tions below for dimensions of Wolf in line and remote blowers Pro ventilation recommendation charts on the following page provide minimum CFM recom mendations according to the cooking appliance and ventilation hood used and blow...

Страница 8: ...In Line BLOWER 110IL 808332 All 27 686 Deep Wall Hoods 600 CFM Remote BLOWER 60REM 801640 PW302718 900 CFM Remote BLOWER 90REM 801641 PW302718 PW362718 PW422718 PW482718 PW542718 1200 CFM Remote BLOWER 120REM 801642 All 27 686 Deep Wall Hoods 1500 CFM Remote BLOWER 150REM 804701 All 27 686 Deep Wall Hoods Pro 27 686 Deep Wall Hoods Model PW302718 PW362718 PW422718 PW482718 PW542718 PW602718 PW6627...

Отзывы: