Page 37
MW24-1100 MICROWAVE OVEN
Component Removal
4-10
#814888 - Revision A - May, 2009
Cavity Temperature Fuse
The cavity temperature fuse is attached to the top left
side of the oven cavity with a screw.
To remove the cavity temperature fuse, the cabinet
case must first be removed. Then, use a needle-nose
pliers to disconnect the “Positive-Lock” wire connectors
from the fuse
mounting screw and lift the fuse off of the oven cavity
AH (Absolute Humidity) Sensor and Sensor Duct
The AH sensor duct is positioned on the outside left
wall of the oven cavity and is held in place with a screw
that passes down through the top left flange of the oven
cavity, into the top of the duct. The AH sensor is
attached to the AH sensor duct with a screw.
AH Sensor -
To remove the AH sensor, the cabinet
case must first be removed. Then, disconnect the AH
sensor wire lead from the back of the control panel
assembly. Extract the sensor mounting screw and pull
the sensor from the sensor duct.
AH Sensor Duct -
To remove the AH sensor duct, first
follow the steps listed above to remove the AH sensor.
After the sensor is removed, extract the duct mounting
screw from the top left flange of the oven cavity, lower
the duct slightly and then pull it from the left wall of the
oven cavity.
Terminal
Push lever
Pull connector
1
2
Lever
Positive
Lock
Connector
Figure 4-24. Disconnect Positive Lock Connectors
Figure 4-25. Cavity Temperature Fuse Removal
Cavity Temperature Fuse
Figure 4-26. AH Sensor & Duct Removal
AH Sensor
AH Sensor