4
|
Wolf Customer Care 800.222.7820
SPECIFICATIONS
Installation Requirements
The drawer microwave oven can be installed in a standard
or flush inset application. Location of the electrical supply
within the oven opening may require additional cabinet
depth. Refer to the chart below.
Finish the edges of the opening. They may be visible when
the drawer is open.
For flush inset installations, a minimum
1
/
8
"
(3)
reveal is
required on the top and sides and
11
/
16
"
(18)
on the bottom.
A sales accessory is required to direct air away from the
unit. Accessories are available through an authorized Wolf
dealer. For local dealer information, visit the find a show-
room section of our website, wolfappliance.com. To ensure
consistent reveals, each corner of the opening must be
exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT
24" Model
125 lbs
(57 kg)
30" Model
125 lbs
(57 kg)
TRIM OVERLAP
24" MODEL
30" MODEL
Top
5
/
16
"
(8)
5
/
16
"
(8)
Bottom
1
/
16
"
(2)
1
/
16
"
(2)
Sides
3
/
4
"
(19)
3
7
/
8
"
(98)
Anti-Tip Blocking
To reduce the risk of tipping, the drawer microwave oven
must be secured in place by anti-tip blocking. The anti-tip
blocking must be provided by the installer. Dimensions will
vary with the installation. Refer to the illustration for your
specific installation on pages 5–6.
When installed to the wall, make sure screws completely
penetrate dry wall and are secured in wood or metal, so
blocking is completely stable. When fastening, verify screws
do not penetrate electrical wiring or plumbing.
The anti-tip blocking prevents serious injury that might result
from the drawer tipping forward and hot food being spilled.
Electrical
Installation must be electrically grounded in accordance
with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70.
The receptacle should be located in the upper left area of
the opening. Refer to the illustrations on pages 5–6. The
receptacle may also be located in an adjacent cabinet within
reach of the power cord. An access hole must be provided
through the cabinet for the power cord.
IMPORTANT NOTE:
The microwave oven is equipped with a
power cord with a 3-prong grounding plug. The power cord
must be plugged into a mating 3-prong grounded outlet. If
you only have a 2-prong outlet, have a qualified electrician
install a properly grounded outlet. If you have any questions
about the grounding or electrical instructions, consult a
qualified electrician or service technician.
ELECTRICAL REQUIREMENTS
Electrical Supply
grounded, 120 VAC, 60 Hz
Service
15 amp dedicated circuit
Receptacle
3-prong grounding-type
Power Cord
4'
(1.2 m)
GROUNDING INSTRUCTIONS
This appliance must be grounded. The drawer microwave
oven is equipped with a cord having a grounding wire with
a grounding plug. It must be plugged into a wall receptacle
that is properly installed and grounded in accordance with
the National Electrical Code and local codes and ordi-
nances. In the event of an electrical short circuit, grounding
reduces risk of electric shock by providing an escape wire
for the electric current.
Rating plate location.
RATING