![Wolf ICBDF30450/S/P Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/wolf/icbdf30450-s-p/icbdf30450-s-p_design-manual_992793005.webp)
|
5
Dual Fuel Ranges
E
A
124
mm
216
mm
G
ELECTRICAL
AND GAS IN
‘A’ LOCATION
ONLY
FRONT VIEW
SIDE VIEW
*Without ventilation hood, 914 mm
minimum clearance countertop to combustible materials,
1200
mm
for char
grill (
broiler
).
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces.
Combustible materials cannot be located within this area.
For island installation, 305 mm
minimum clearance back of range to combustible rear wall above countertop.
330
mm
457
mm
152
mm
937 mm
TO COOKING
SURFACE
W
OPENING WIDTH
762 mm
TO
1200
mm
TO BOTTOM OF
VENTILATION HOOD
*
51
mm
Dual Fuel Range
INSTALLATION
OPENING WIDTH
W
A
76 cm Range
762 mm
260 mm
91 cm Range
914 mm
413 mm
122 cm Range
1219 mm
464 mm
152 cm Range
1524 mm
464 mm
Note - A minimum of clearance of 1200mm is required from the
c
hargrill
b
urner to the filter of the rangehood.
AUSTRALIA ONLY
NOTE
- refer below for
minimum clearance for
models with chargrill
Содержание ICBDF30450/S/P
Страница 1: ...Design Guide Dual Fuel Ranges ICB REVISED 7 2022...