4
Dual Fuel Ranges
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
Locate the electrical supply flush with the wall or floor and
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit servicing only this appliance
is required.
Performance may be compromised if the electrical supply
is less than 240 volts.
ELECTRICAL REQUIREMENTS
ELECTRICAL SUPPLY
Single Phase
220–240 V AC, 50/60 Hz
3-Phase
380–415 V AC, 50 Hz
MAX CONNECTED LOAD
SINGLE PHASE
3-PHASE
76 cm Range
20.5 A
19.2 A
91 cm Range
20.5 A
19.2 A
122 cm Range
38.9 A
19.2 A
152 cm Range
40.8 A
19.2 A
Planning Information
When installing against a combustible surface, a minimum
254 mm riser is required for a 91 cm Wolf Dual Fuel Range
with charbroiler or griddle and all 122 cm and 152 cm
models. Follow all minimum clearances to combustible
surfaces shown in the illustration on the following page.
GAS REQUIREMENTS
Installation must conform with all applicable gas codes.
Locate the gas supply within the shaded area shown in the
illustration on the following page.
A gas supply line of 19 mm rigid pipe must be provided to
the range. If local codes permit, a certified, .9 m long, 13
mm or 19 mm ID flexible metal appliance connector is
recommended to connect the units ISO 7/1-14
(1/2" BSP)
female inlet to the gas supply line.
GAS SUPPLY PRESSURE
WC
Natural Gas
1 kPa
LP Gas
2.75 kP
a