4
|
English
SPECIFICATIONS
FRONT VIEW
SIDE VIEW
483 mm
PLATFORM DEPTH
FRONT VIEW
SIDE VIEW
*152 mm back from countertop cut-out when internal blower is rear mounted.
NOTE: Internal blower 152 mm round, side, rear or bottom discharge. Remote blower 254 mm round, rear discharge.
Centerline indicates center of downdraft cut-out.
540
mm
210
mm*
TOP VIEW
W
DOWNDRAFT
CUT-OUT WIDTH
210 mm*
540 mm
594 mm
RANGETOP OPENING
68 mm
E
E
Downdraft
INSTALLATION WITH SEALED BURNER RANGETOP
CUT-OUT WIDTH
MODEL
W
ICBDD30
699 mm
TRANSITION
For internal blowers, remove the existing 254 mm round
transition. Refer to the illustration below.
For remote blowers being discharged from the front, leave
the 254 mm round transition in place.
For remote blowers being discharged from the rear, remove
the 254 mm round transition from the front and solid cover
from the rear of the downdraft, then reinstall the 254 mm
transition on the rear and solid cover on the front.
INSTALLATION
Remove transition.
Installation
DOWNDRAFT
1
Install the top mounting brackets using the #4 sheet
metal screws provided. Refer to the illustration below.
2
Install the lower mounting brackets using the #8 x 32
sheet metal screws provided, but do not tighten. The
brackets will need to be adjusted once the downdraft is
placed in the opening. Refer to the illustration below.
Top mounting bracket.
Bottom leveling bracket.