Wolf Dual Fuel Ranges
44
ELECTRICAL AND GAS REQUIREMENTS
Wolf dual fuel ranges have a terminal block that allows for
a 3-wire or 4-wire installation. A separate, grounded
220-240 V AC, 50/60 Hz electrical supply is required with
its own circuit breaker.
A gas supply line of 19 mm rigid pipe must be provided to
the range. If local codes permit, a certified, .9 m long, 13
mm or 19 mm ID flexible metal appliance connector is
recommended to connect the range to the gas supply line.
Wolf dual fuel ranges are designed to operate on natural
gas at 20 mb pressure or LP gas at 37 mb pressure.
Planning Information
Available in four widths, Wolf dual fuel ranges are
designed to fit a 762 mm, 914 mm, 1219 mm or 1530 mm
opening.
IMPORTANT NOTE:
When installing against a combustible
surface, a minimum 254 mm riser is required for a 914 mm
dual fuel range with charbroiler or griddle/teppan-yaki and
all 1219 mm and 1524 mm models. Follow all minimum
clearances to combustible surfaces shown in the installa-
tion illustration on the following page.
It is recommended that you use a Wolf pro ventilation
hood with the dual fuel range. If the range is to be
installed without ventilation, a 914 mm minimum clear-
ance, 1118 mm for charbroiler, from countertop to
combustible materials above the range is required. Refer
to page 67 for pro ventilation.
Oven Specifications
INTERIOR CAPACITY
L
457 mm Oven
71
762 mm Oven
127
914 mm Oven
153
INTERIOR DIMENSIONS
W
H
D
457 mm Oven
356 mm
419 mm
483 mm
762 mm Oven
635 mm
419 mm
483 mm
914 mm Oven
762 mm
419 mm
483 mm
Burner Rating
kW
kW
SURFACE BURNERS
HIGH
SIMMER
(3 or 5) Large
4.8
.3
(1) Small
2.7
.1
OPTIONAL FEATURES
NATURAL
LP
Infrared Charbroiler
5.6
5.15
Infrared Griddle/Teppan-Yaki
5.6
5.15
French Top
4.8
4.0
Maximum Connected Load
DUAL FUEL RANGE
SINGLE PHASE
3PHASE
762 mm and 914 mm
19 amps
18 amps
1219 mm
35 amps
18 amps
1524 mm
38 amps
18 amps