![Wolf ICBCT15G/S Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/wolf/icbct15g-s/icbct15g-s_design-manual_992092037.webp)
Wolf Integrated Modules
37
wolfappliance.com/specs
Planning Information
When multiple cooktops or modules are installed side by
side, the dimensions provided in the chart are derived by
adding 32 mm additional space for each additional unit, to
give you the total countertop cut-out width. Dimensions
include the optional filler strip available through your Wolf
dealer. For local distributor information, visit the interna-
tional section of our website, wolfappliance.com.
Refer to specifications on the following pages for specific
installation requirements and limitations for each integrated
module. Review specific installation instructions for
product-to-product capabilities. Installation specifications
for the induction and electric cooktops can be found on
page 24 and for the gas cooktop on page 32.
IMPORTANT NOTE:
Wolf does not recommend the use of
downdraft ventilation with the grill, steamer or fryer
modules.
ELECTRICAL REQUIREMENTS
Wolf electric modules require a separate, grounded 3-wire
220-240 V AC, 50/60 Hz power supply. Gas modules
require a separate, grounded 220-240 V AC, 50/60 Hz
power supply and a grounded 3-prong receptacle located
within reach of the 1.8 m power cord. Total amps for the
electric cooktop is 16. Total amps for the electric grill,
steamer and fryer is 12. Total amps for gas and multi-
function cooktops is less than one.
When multiple cooktops or modules are installed side by
side, each unit must have its own separate electrical
supply.
GAS REQUIREMENTS
A gas supply line of 19 mm rigid pipe must be provided to
the gas module. If local codes permit, a certified, .9 m long,
13 mm or 19 mm ID flexible metal appliance connector is
recommended to connect the module to the gas supply
line.
When multiple gas cooktops or modules are installed next
to one another, they can receive their gas supply from a
common line.
Wolf gas modules are designed to operate on natural gas
at 20 mb pressure or LP gas at 37 mb pressure.
Multiple Cooktops
COUNTERTOP CUT-OUT
WIDTH
2 Modules
743 mm
3 Modules
1130 mm
4 Modules
1518 mm
762 mm Cooktop / Module
1124 mm
762 mm Cooktop / 2 Modules
1511 mm
914 mm Cooktop / Module
1276 mm
64 mm
min
489 mm
CUT-OUT
DEPTH
CUT-OUT WIDTH
356 mm
MODULE
CUT-OUT
WIDTH
FRONT OF COUNTERTOP
Countertop cut-out.