background image

4

B E F O R E

Y O U S T A R T

Proper installation is your responsibility.
Have a qualified person install this cooktop.
You must also assure that electrical installa-
tion is adequate and in compliance with all
local codes and ordinances.

Prior to installation, ensure that the local
distribution conditions (nature of the gas
and gas pressure) and the adjustment of
the appliance are compatible.

Proper gas supply connection must be
available; refer to Gas Supply Requirements
on page 10. Electrical ground is required;
see Electrical Requirements on page 11.

The adjustment conditions for this appli-
ance are stated on the label (or rating
plate). The data plate can be found on the
underside of the cooktop.

W O L F

G A S C O O K T O P S

Rating plate location

Location of rating

plate under cooktop

R A T I N G P L A T E
I N F O R M A T I O N

Model Number

Serial Number

IMPORTANT NOTE:

This manual covers installation instructions
for three cooktop models. i.e.:
2 burner cooktop - model ICBCG15
4 burner cooktop - model ICBCTG304
5 burner cooktop - model ICBCG365

COOKTOPS installation manual:Intl Gas Cooktops Install  31/3/10  2:24 PM  Page 4

Содержание ICBCG15

Страница 1: ... INSTRUCTIONS Model numbers ICBCG365 This cooktop is approved for use with Leave instructions with the owner COOKTOPS installation manual Intl Gas Cooktops Install 31 3 10 2 24 PM Page 1 ICBCG15 ICBCG304 Natural Gas Propane Gas ...

Страница 2: ...orma tion that is especially relevant to a problem free installation signals a situation where minor injury or product damage may occur if you do not follow instructions states a hazard that may cause serious injury or death if precautions are not followed WOLF is a registered trademark of Wolf Appliance Inc COOKTOPS installation manual Intl Gas Cooktops Install 31 3 10 2 24 PM Page 2 CONTACT INFO...

Страница 3: ...lation for example opening of a window or more effective ventila tion for example increasing the level of mechanical ventilation where present This appliance shall be installed in accordance with the regula tions in force and only used in a well ventilated space Read the instructions before installing or using this appliance Installer Please read the entire Installation Instructions prior to insta...

Страница 4: ...Requirements on page 10 Electrical ground is required see Electrical Requirements on page 11 The adjustment conditions for this appli ance are stated on the label or rating plate The data plate can be found on the underside of the cooktop W O L F GAS COOKTOPS Rating plate location Location of rating plate under cooktop R AT I N G P L AT E I N F O R M AT I O N Model Number Serial Number IMPORTANT N...

Страница 5: ... be away from strong draft areas such as windows doors and strong heating vents or fans Do not obstruct flow of combustion and ventilation air This appliance is not connected to a combustion products evacuation device It shall be installed and connected in accor dance with current installation regulations Particular attention shall be given to the relevant requirements regarding ventilation SITE P...

Страница 6: ...x 762 mm COUNTERTOP TO COMBUSTIBLE MATERIALS ABOVE COOKTOP 64 mm 127 mm LOCATION OF GAS SUPPLY MAY ALSO EXTEND 127 mm ON FLOOR FROM BACK WALL FRONT OF COUNTERTOP 64 mm min 495 mm COOKTOP CUT OUT DEPTH W O L F GAS COOKTOPS Overall Dimensions Countertop Cut Out 381 mm OVERALL WIDTH 533 mm OVERALL DEPTH 102 mm M O D E L I C B C G1 5 D I M E N S I O N S Overall Width 381 mm Overall Height 102 mm Overa...

Страница 7: ...mmended that the electrical and gas supply be placed in the base cabinet to the right of the oven Refer to installation instructions provided with the built in oven for additional specifications If the Model ICBCG304 is installed above cabinets the gas and electrical placement is not critical A grounded outlet needs to be placed within 1 2 m of the right rear of the cooktop IMPORTANT NOTE When mul...

Страница 8: ... COMBUSTIBLE MATERIALS ABOVE COOKTOP 610 mm min Minimum clearance from both side edges of cooktop cut out to combustible materials up to 457 mm above countertop Minimum clearance from rear edge of cooktop cut out to combustible materials up to 457 mm above countertop 889 mm COOKTOP CUT OUT WIDTH 889 mm COOKTOP CUT OUT WIDTH 991 mm RECOMMENDED CABINET WIDTH 914 mm min 102 mm 254 mm 89 mm E G 914 mm...

Страница 9: ... connected to the gas supply with upstream connection of an isolation valve in accor dance with the respectively valid regulations We recommend that the isolation valve be fitted prior to the cooktop to enable isolation of the cooktop from the gas supply The valve must be easily accessible at all times This appliance may be connected with a hose assembly class B or class D If connected with a hose...

Страница 10: ...tubing size can be 13 mm minimum LP gas suppliers usually determine the size and materials used on the system If local codes permit a flexible metal appliance connector is recommended for connecting this cooktop to the gas supply line Do not kink or damage the flexible connector when moving the cooktop You will need to determine the fittings required depending on the size of your gas supply line f...

Страница 11: ...his appliance when installed must be electri cally grounded in accordance with local codes COOKTOPS installation manual Intl Gas Cooktops Install 31 3 10 2 24 PM Page 11 The appliance is supplied with a cord and appliance can be hard wired to a terminal box or plug Do not remove ground prong Supply must be properly earthed failure to follow these instructions can result in electric shock fire or d...

Страница 12: ...p is parallel to the front edge of the countertop Lift the entire cooktop to make adjustments and align the rear edge with the pencil line Attach the brackets to the burner box Insert the 89 mm clamping screws into the brackets Use a screwdriver to tighten the clamping screws against the underside of the counter top Refer to the illustration below Do not overtighten screws 12 G A S L E A K T E S T...

Страница 13: ...nsure that the flames do not extinguish when you reduce to low flame quickly Check correct operation of each burner individually and in combination F L A M E H E I G H T A N D A P P E A R A N C E The flame on natural gas should be blue with a deeper blue core and no yellow tipping If burners show any abnormality check that burner heads are correctly located and refer to the trouble shooting guide ...

Страница 14: ...nd that the electri cal connection to the appliance has not been disconnected A power outage may also have caused a disruption in service For service call 1300 808 859 Made in USA Electrical compliance in accordance with AS NZS3100 240 V AC 10 amps 50 Hz Model No ICBCG365T S ICBCG365P S Gas type NG LPG Test point press kPa 1 0 2 75 Injector sizes mm RAPID ULTRA RAPID SEMI RAPID 1 59 2 05 1 40 0 94...

Страница 15: ...T BLACK RIV GAS VALVE RED RED RED RED WHITE GRN YEL BLACK RIGHT REAR LEFT REAR LEFT FRONT BLACK WHITE WHITE BLACK LEFT FRONT POWER CORD RED RIV GAS VALVE WHITE BLACK RIGHT REAR LEFT REAR RIGHT FRONT CTR REAR GRN YEL BLACK RED RED RED BLACK WHITE WIRING D I A G R A M S Model ICBCG304 Model ICBCG365 COOKTOPS installation manual Intl Gas Cooktops Install 31 3 10 2 24 PM Page 15 ...

Страница 16: ...OPS installation manual Intl Gas Cooktops Install 31 3 10 2 24 PM Page 16 MF068 Sub Zero Group Australia Pty Ltd Level 10 469 La Trobe Street Melbourne Victoria 3000 Phone 61 3 9600 2218 subzero wolf com au ...

Отзывы: