Wolf I363418 Скачать руководство пользователя страница 9

9

R E M O T E B L O W E R

IMPORTANT NOTE:

Before turning

the power on, make sure the blower

is in the "OFF" position. Use wire con-

nectors or wire nuts approved by UL

or C/UL. Refer to installation instruc-

tions provided with each blower to

verify island or roof cut-outs.

STEP 1: Plan the Installation

1)

Locate the blower so the length of

the duct run and number of elbows
and transitions are kept to a mini-
mum.

2)

Where possible, blower should be

located between island studs or roof
rafters.

3)

Avoid pipes, wires or other duct-

work that may be running through
the island.

4)

Be sure that there is enough space

for any transitions that may be need-
ed between the blower and the con-
necting ductwork.

5)

For best performance, locate tran-

sitions nearest the blower.

STEP 2: Connect Remote Blower

NOTE:

Always refer to all blower

installation instructions provided with
the blower for additional mounting
and wiring instructions.

1)

Remove cover from wiring box

inside of hood shell. Remove wiring
box knockout.

2)

Feed 20” of inbound (Romex)

power cable through the knockout
opening hole and into the wiring
box. Secure the cable to wiring box
with an appropriate connector for
type of cable being used. 

Connect

leads as follows:

• Black (L1) to black (loose) in the J
box from the switch.

• Neutral to neutral (loose) in the J
box from the switch.

3)

Wiring Remote Blower:

Follow

wiring instructions at the blower as
outlined in the particular blower
installation instructions. Black (L1) to
black, white (neutral) to white – or
white to blue, or white to brown
(depending on model) and green to
grounding screw. Run remote blower
cable (ROMEX) to the hood.

Feed 20”of (ROMEX) power cable
through the knockout opening hole
and into the wiring box on the
rough-in plate of hood. Secure the
cable to wiring box with an appropri-
ate connector.

Locate cord assembly provided with
the remote blower. The cord assem-
bly has two leads, black (L1) and
white (neutral). Connect these leads
to the leads from the blower, black to
black and white to white.

Connect ALL green and bare wires
together to the ground screw in the
wiring box.

4)

Plug cord assembly into receptacle

located near the center of the hood
shell. Use clips on hood interior to
keep excess power cord away from
moving parts.

5)

Re-install wiring box cover and

screws. Make sure all wires are secure
and that no wires are pinched
between cover and box.

        24

1/2

"(622)

      15

1/2

"(394)

28

1/4

"(717)

20

3/4

"(527)

24

3/4

"(629)

14"(356)

        4

3/4

"(121)

10"(254)

DIAMETER

Remote blower dimensions – 600 CFM (801640) and
900 CFM (801641)

10"(254)

DIAMETER

          14

3/4

"(375)       

29

1/2

"(749)

29

1/2

"(749)

18"(457)

22"(559)

10

1/8

"(257)   

       7

1/4

"(184)

   10"(254)

Remote blower dimensions – 1200 CFM
(801642)

10"(254)

DIAMETER

         14

3/4

"(375)  

29

1/2

"(749)

29

1/2

"(749)

21"(533)

25"(635)

10

3/8

"(264)

      7

1/4

"(181)

10"(254)

Remote blower dimensions – 1500 CFM
(804701)

P

R O

S

E R I E S

I

S L A N D

H

O O D

I

N S T A L L A T I O N

Содержание I363418

Страница 1: ...P R O S E R I E S I S L A N D H O O D S I N S T A L L A T I O N I N S T R U C T I O N S...

Страница 2: ...ust be completed by a qualified installer or service agency Before you begin installation read these instructions completely and carefully INSTALLER please retain these instructions for local inspecto...

Страница 3: ...re 16 gauge stainless steel shell Transition with backdraft damper included Optional decorative rail assembly in stain less platinum brass or copper finish Hood must be specifically preordered and con...

Страница 4: ...recommends installing a back draft damper in all installations included with hood In cold weather installations a back draft damper is necessary to minimize the backflow of cold air into the room 4 Wo...

Страница 5: ...t Part number 805669 18 457 HEIGHT OF HOOD 34 864 DEPTH OF HOOD 36 914 WIDTH OF HOOD 30 TO 36 762 914 TO COOKING SURFACE COOKING SURFACE LOCATION OF ELECTRICAL CENTERED THROUGH TOP OF HOOD 30 TO 36 76...

Страница 6: ...aming for con duit wiring See Internal Blower on page 8 for overall dimensions and electrical requirements See installa tion instructions provided with the blower for mounting and installation informa...

Страница 7: ...and tighten into 2x4 framing DO NOT OVER TIGHTEN SCREWS 8 Connect the 10 round ductwork to the hood transition using sheet metal screws or duct tape 9 Make electrical connections See Install Wiring on...

Страница 8: ...uch as a tag to the service panel P R O S E R I E S I S L A N D H O O D I N S T A L L A T I O N I N T E R N A L B L O W E R IMPORTANT NOTE Before turning the power on make sure the blower is in the OF...

Страница 9: ...the switch 3 Wiring Remote Blower Follow wiring instructions at the blower as outlined in the particular blower installation instructions Black L1 to black white neutral to white or white to blue or...

Страница 10: ...into place Lines of fil ters must run vertically and align with drip cups 5 Adjust filters to fill space by sliding filters left to right CAUTION Installing a duct cover assembly will impact all aspec...

Страница 11: ...ods DUC12COVER54I 12 duct cover for 54 island hoods DUC12COVER66I 12 duct cover for 66 island hoods P R O S E R I E S I S L A N D H O O D A C C E S S O R I E S B L O W E R S Internal Blowers IBLOWER 1...

Страница 12: ...rail for 54 island hoods RAIL 66 SS Decorative rail for 66 island hoods Platinum Finish RAIL 36 PLT Decorative rail for 36 island hoods RAIL 42 PLT Decorative rail for 42 island hoods RAIL 54 PLT Dec...

Страница 13: ...t 800 332 9513 or check our website www wolfappliance com When calling for service you will need the island hood model and seri al numbers Both numbers are listed on the rating plate located on the le...

Страница 14: ...14 CUT OUT FOR LOGO PLACEMENT BOTTOM EDGE OF HOOD FOLD LINE FOR LOGO PLACEMENT LEFT OUTER EDGE OF HOOD...

Страница 15: ...Wolf Appliance Company LLC P O Box 44848 Madison WI 53744 800 332 9513 www wolfappliance com 805050 7 03...

Отзывы: