I N S T A L L T H E T O P C O V E R
Models DD30 and DD36 only
IMPORTANT NOTE: Model DD45 comes with
the top cover already installed.
Press the UP/DOWN button on the control
module.
Remove shipping brackets from the down-
draft chimney.
Align the mounting brackets on the back
surface of the top cover with the corner
mounting positions on top of downdraft
chimney.
Screw the top cover mounting brackets into
the mounting holes on downdraft chimney
with the four screws provided. Make sure
that the top cover is secure and runs flush
with the front edge of the downdraft.
14
W O L F
D OW N D R A F T
V E N T I L A T I O N S Y S T E M S
D O W N D R A F T
I N S TA L L AT I O N
R E M O T E B L O W E R W I R I N G
Models DD30R, DD36R and DD45R
Mount a standard 120 V AC electrical box,
with 3-pronged grounded receptacle, inside
the cabinet or adjacent cabinet. Make sure
it is located within the reach of the down-
draft’s 2
1
/
2
' (.8 m) power cord.
Run the appropriate power cable into the
cabinet and connect it to electrical box and
outlet.
The remote blower may not exceed a 6.0
amp rating.
Run 2-wire plus ground power cable from
the remote blower to the electrical box on
the remote blower adapter plate.
Connect the downdraft wiring to the power
cable from the remote blower. Wire black to
black, white to white and green to green or
bare wire. Refer to the illustration below.
Replace the electrical box cover.
Plug the power cord of the downdraft into
the outlet.
IMPORTANT NOTE: For mounting and
installation of the remote blower, refer to the
installation instructions for your specific
blower.
black to black
white to white
green to green
120 VAC line in
Wiring connections